The control valve head uses a meter to count the gallons of water being treated through the system. Once the
gallons programmed in the unit have been exhausted, the system will regenerate. The total gallons of treatable
water the system can produce is based on the system size, family size, and the hardness level of the feed water.
A simple calculation is done to determine the amount of gallons to input during the “Setting 3” programming
portion of the installation.
NOTE: This calculation must be completed to program the unit:
Example:
System Capacity: AS-HL32C System/32,000 Grains
Feed Water Hardness: 25 GPG (must be tested on-site by the end user or installer)
Number of People: 3
1,055 Gallons would be inputted for Total Gallons during “Setting 3” programming.
If the hardness level is given in ppm or mg/L, it can be converted to Grains Per Gallon by dividing
the value by 17.1.
Total Gallons = System Capacity in Grains (see chart below) / Hardness in (GPG) Grains
Per Gallon (determined by water test) - Number of People X 75 Gallons
( _
32,000
_Grains / ____
25
___GPG) - ( ____
3
_____ People X 75 Gallons)
___
1,280
__Gallons - ___
225
___Gallons = __
1,055
__ Total Gallons
Parameter Aquasure Water Softener
Medium Salt Curve Capacity Setting 24,000-40,000
Brine Fill Settings in Minutes 12
GALLONS CALCULATION TOOL