Manual

877.768.2717 fax 877.276.POOL Outside the U.S.: 1.805.620.5060 fax +1.949.336.1940
info@aquastarpoolproducts.com www.aquastarpoolproducts.com 9
g. 6
“A”
2" OR 2-1/2" PIPE
FIELD FABRICATED
SUMP INSTALLATION
(ONE, TWO, OR THREE PORTS)
INTERIOR
POOL FINISH
SHOTCRETE / GUNITE
EARTH
GRAVEL
OPTIONAL SINGLE CONNECTION
OR HYDROSTATIC VALVE
1 PUMP WITH 3" OR 4" TEE
2 SEPARATE PUMP SYSTEM CONNECTIONS
AV STYLE OR FLAT GRATE
(32CDAV) (32CDFL)
FRAME / MUD-RING
IMPORTANT
• Models:32CDFLFRxxx,32CDLTFRxxxor
32CDAVFRxxx. 32CDBTFRxxx, 32CDPHFRxxx
(AV=Anti-Vortex)
• Singleormultipledrainuse
• AtIAPMO(anationallyrecognized
testing lab), all AquaStar channel drains have
been tested to
three inches in sump depth –
eld-fabricated or manufactured
• AllAquaStarchanneldrainsare
VGB 2008 compliant
• Plumbing to one or two pumps plus skimmer
equalizerareapproved–DONOTexceed
maximum ow rate of outlet cover for total
system
• One-, two- or three-pipe connections are
approved at any port or conguration under
manufactured sump or eld-fabricated sump
• Ashouldbeaminimumofthree (3)inches to
the bottom of cover, must extend the entire
length of the cover.
• Any plumbing conguration is approved but
do not exceed maximum ow rate
• NOTE: 32CDPHFRxxx Flow rate is 256 GPM
(oor) / 196 GPM (wall) when more than one
port is used.
FIELD FABRICATED SUMP INSTALLATION (ONE, TWO or THREE PORTS)
For additional information on proper drain installation refer to The Association of Pool &
Spa Professionals ANSI/APSP-7 Standard and the U.S. Consumer Product Safety Commission
GuidelinesforEntrapmentHazard.
g. 7
FIELD FABRICATED SUMP INSTALLATION (SINGLE PIPE CONSTRUCTION)
IMPORTANT
• Models:32CDFLFRxxx,32CDLTFRxxx,
or 32CDAVFRxxx. 32CDBTFRxxx,
32CDPHFRxxx (AV=Anti-Vortex)
• Singleormultipledrainuse
• AtIAPMO(anationallyrecognized
testing lab), all AquaStar Channel
Drains have been tested to 3 inches
in sump depth – eld-fabricated or
manufactured
• AllAquaStarchanneldrainsare
VGB 2008 compliant
• Plumbing to one or two pumps plus
skimmerequalizerareapproved–
DO NOT exceed maximum ow rate
of outlet cover for total system
• One-, two- or three-pipe connections
are approved at any port or
conguration under manufactured
sump or eld-fabricated sump
• Ashouldbeaminimumofthree
inches to the bottom of cover
• Any plumbing conguration is
approved but do not exceed
maximum ow rate
For additional information on proper drain installation refer to The Association of Pool &
Spa Professionals ANSI/APSP-7 Standard and the U.S. Consumer Product Safety Commission
GuidelinesforEntrapmentHazard.