Manual
877.768.2717 fax 877.276.POOL Outside the U.S.: 1.805.620.5060 fax +1.949.336.19408
info@aquastarpoolproducts.com www.aquastarpoolproducts.com
MANUFACTURED SUMP INSTALLATION (DUAL PUMP WITH
HYDROSTATIC VALVE INSTALLATION)
g. 5
MANUFACTURED
SUMP INSTALLATION
(DUAL PUMP WITH HYDROSTATIC VALVE INSTALLATION)
INTERIOR
POOL FINISH
SHOTCRETE / GUNITE
EARTH
GRAVEL
PUMP #2
1-1/2", 2", 2-1/2",
3" OR GREATER PIPE
AV STYLE OR FLAT GRATE
(32CDAV) (32CDFL)
FRAME / MUD-RING
PUMP #1
1-1/2", 2", 2-1/2",
3" OR GREATER PIPE
OPTIONAL HYDROSTATIC VALVE
IMPORTANT
• Models:32CDFLxxx, 32 CDAVxxx, 32CDFLVxxx,
32FLACxxx, 32CDAVVxxx, 32CDAVACxxx,
32CDBTxxx, 32CDLTxxx, 32CDLTVxxx,
32CDPHxxx, 32CDPHVxxx (AV=Anti-Vortex)
• Singleormultipledrainorpipeuse
• AtIAPMO(anationallyrecognized
testing lab), all AquaStar channel drains have
been tested to
three inches in sump depth –
eld-fabricated or manufactured
• AllAquaStarchanneldrainsare
VGB 2008 compliant
• Plumbing to one or two pumps plus skimmer
equalizerareapproved–DONOTexceed
maximum ow rate of outlet cover for total
system
• One-, two- or three-pipe connections are
approved at any port or conguration under
manufactured sump or eld-fabricated sump
• Any plumbing conguration is approved but do
not exceed maximum ow rate
• NOTE: 32CDPHxxx, 32CDPHVxxx, 32CDPHTSxxx
Flow rate is 256 GPM (oor) / 196 GPM (wall)
when in this conguration
IMPORTANT
• Models:32CDFLxxx, 32 CDAVxxx,
32CDFLVxxx, 32FLACxxx, 32CDAVVxxx,
32CDAVACxxx, 32CDBTxxx, 32CDLTxxx,
32CDLTVxxx, 32CDPHxxx, 32CDPHVxxx,
32CDPHTSxxx (AV=Anti-Vortex)
• Singleormultipledrainorpipeuse
• AtIAPMO(anationallyrecognized
testing lab), all AquaStar channel drains have
been tested to
three inches in sump depth –
eld-fabricated or manufactured
• AllAquaStarchanneldrainsare
VGB 2008 compliant
• Plumbing to one or two pumps plus skimmer
equalizerareapproved–DONOTexceed
maximum ow rate of outlet cover for total
system
• One-, two- or three-pipe connections are
approved at any port or conguration under
manufactured sump or eld-fabricated sump
• Any plumbing conguration is approved but
do not exceed maximum ow rate
• NOTE: 32CDPHxxx, 32CDPHVxxx,
32CDPHTSxxx Flow rate is 256 GPM (oor) /
196 GPM (wall) when in this conguration
MANUFACTURED SUMP INSTALLATION (BOOSTER & CIRCULATING PUMP INSTALLATION)
For additional information on proper drain installation refer to The Association of Pool &
Spa Professionals ANSI/APSP-7 Standard and the U.S. Consumer Product Safety Commission
GuidelinesforEntrapmentHazard.
g. 4
MANUFACTURED
SUMP INSTALLATION
(BOOSTER & CIRCULATING PUMP INSTALLATION)
INTERIOR
POOL FINISH
SHOTCRETE / GUNITE
EARTH
GRAVEL
BOOSTER PUMP
1-1/2", 2", 2-1/2",
3" OR GREATER PIPE
AV STYLE OR FLAT GRATE
(32CDAV) (32CDFL)
FRAME / MUD-RING
CIRCULATING PUMP
1-1/2", 2", 2-1/2",
3" OR GREATER PIPE
OPTIONAL HYDROSTATIC VALVE