Manual
877.768.2717 fax 877.276.POOL Outside the U.S.: 1.805.620.5060 fax +1.949.336.1940
info@aquastarpoolproducts.com www.aquastarpoolproducts.com 7
IMPORTANT
• Models:32CDFLxxx, 32 CDAVxxx,
32CDFLVxxx, 32FLACxxx,
32CDAVVxxx, 32CDAVACxxx,
32CDBTxxx, 32CDLTxxx, 32CDLTVxxx,
32CDPHxxx, 32CDPHVxxx,
32CDPHTSxxx (AV=Anti-Vortex)
• Singleormultipledrainorpipeuse
• AtIAPMO(anationallyrecognized
testing lab), all AquaStar channel
drains have been tested to
three inches in sump depth –
eld-fabricated or manufactured
• AllAquaStarchanneldrainsare
VGB 2008 compliant
• Plumbing to one or two pumps plus
skimmerequalizerareapproved–
DO NOT exceed maximum ow rate
of outlet cover for total system
• One-, two- or three-pipe connections
are approved at any port or
conguration under manufactured
sump or eld-fabricated sump
• Any plumbing conguration is
approved but do not exceed
maximum ow rate
MANUFACTURED SUMP INSTALLATION (SINGLE PORT / PUMP INSTALLATION)
For additional information on proper drain installation refer to The Association of Pool &
Spa Professionals ANSI/APSP-7 Standard and the U.S. Consumer Product Safety Commission
GuidelinesforEntrapmentHazard.
g. 2
MANUFACTURED
SUMP INSTALLATION
(SINGLE PORT / PUMP INSTALLATION)
POOL FINISH
INTERIOR
SHOTCRETE / GUNITE
EARTH
GRAVEL
OPTIONAL SINGLE CONNECTION OR HYDROSTATIC VALVE
SINGLE PIPE CONNECTION ON
ANY OF THREE PORTS.
1-1/2", 2", 2-1/2", 3" OR GREATER PIPE
AV STYLE OR FLAT GRATE
(32CDAV) (32CDFL)
FRAME / MUD-RING
PLUG PORTS NOT BEING USED
TO PUMP
MANUFACTURED SUMP INSTALLATION (THREE PORT TEE / SINGLE PUMP INSTALLATION)
IMPORTANT
• Models:32CDFLxxx, 32 CDAVxxx,
32CDFLVxxx, 32FLACxxx, 32CDAVVxxx,
32CDAVACxxx, 32CDBTxxx, 32CDLTxxx,
32CDLTVxxx, 32CDPHxxx, 32CDPHVxxx,
32CDPHTSxxx (AV=Anti-Vortex)
• AtIAPMO(anationallyrecognized
testing lab), all AquaStar channel drains have
been tested to
three inches in sump depth –
eld-fabricated or manufactured
• AllAquaStarchanneldrainsare
VGB 2008 compliant
• Plumbing to one or two pumps plus skimmer
equalizerareapproved–DONOTexceed
maximum ow rate of outlet cover for total
system
• One-, two- or three-pipe connections are
approved at any port or conguration under
manufactured sump or eld-fabricated sump
• Any plumbing conguration is approved but
do not exceed maximum ow rate
• NOTE: 32CDPHxxx, 32CDPHVxxx,
32CDPHTSxxx Flow rate is 300 GPM (oor) /
168 GPM (wall) when three ports and at least
2 1/2” pipe are used.
g. 3
MANUFACTURED
SUMP INSTALLATION
(THREE PORT TEE / SINGLE PUMP INSTALLATION)
POOL FINISH
INTERIOR
SHOTCRETE / GUNITE
TEE THREE PORTS TOGETHER
1-1/2", 2", 2-1/2", 3" OR GREATER PIPE
AV STYLE OR FLAT GRATE
(32CDAV) (32CDFL)
FRAME / MUD-RING
TO PUMP
GRAVEL
EARTH