Manual

877.768.2717 fax 877.276.POOL Outside the U.S.: 1.805.620.5060 fax +1.949.336.19406
info@aquastarpoolproducts.com www.aquastarpoolproducts.com
MANUFACTURED SUMP INSTALLATION (ONE, TWO or THREE PORTS)
IMPORTANT
• Models:32CDFLxxx, 32 CDAVxxx, 32CDFLVxxx,
32FLACxxx, 32CDAVVxxx, 32CDAVACxxx,
32CDBTxxx, 32CDLTxxx, 32CDLTVxxx,
32CDPHxxx, 32CDPHVxxx, 32CDPHTSxxx
(AV=Anti-Vortex)
• Singleormultipledrainorpipeuse
• AtIAPMO(anationallyrecognized
testing lab), all AquaStar channel drains have
been tested to
three inches in sump depth –
eld-fabricated or manufactured
• AllAquaStarchanneldrainsare
VGB 2008 compliant
• Plumbing to one or two pumps plus skimmer
equalizerareapproved–DONOTexceed
maximum ow rate of outlet cover for total
system
• One-, two- or three-pipe connections are
approved at any port or conguration under
manufactured sump or eld-fabricated sump
• Any plumbing conguration is approved but do
not exceed maximum ow rate!
• NOTE: 32CDPHxxx, 32CDPHVxxx, 32CDPHTSxxx
Flow rate is 256 GPM (oor) / 196 GPM (wall)
when more than one port is used.
g. 1
MANUFACTURED
SUMP INSTALLATION
(ONE, TWO, OR THREE PORTS)
INTERIOR
POOL FINISH
SHOTCRETE / GUNITE
EARTH
GRAVEL
OPTIONAL SINGLE CONNECTION
OR HYDROSTATIC VALVE
2" OR 2-1/2" PIPE
1 PUMP WITH 3" OR 4" TEE
2 SEPARATE PUMP SYSTEM CONNECTIONS
AV STYLE OR FLAT GRATE
(32CDAV) (32CDFL)
SUMP
ALL MODELS LISTED BELOW = ANTIENTRAPMENT/ANTIVORTEX AND
FOR SINGLE OR MULTIPLE USE
MAX FLOW RATES (PER OUTLET) MOUNTING POSITIONS (xxx=COLOR SUFFIX)
Model 32CDFLxxx (and
32CDFLFRxxx,
32CDFLVxxx,
32CDFLACxxx)
32CDLTxxx (and
32CDLTFRxxx,
32CDLTVxxx)
32CDAVxxx (and
32CDAVFRxxx,
32CDAVVxxx,
32CDAVACxxx)
32PDxxx
(min. 2” pipe)
32CDBTxxx,
32CDBTFRxxx
32CDPHxxx (and
32CDPHFRxxx,
32CDPHVxxx,
32CDPHTSxxx)
(min. 2” pipe)
Floor
316 GPM @ 3.9 fps 196 GPM @ 1.3 fps 236 GPM @ 3.4 fps 196 GPM @ 2.3 fps 120 GPM @ 1.2 fps 268 GPM @ 3.1 fps
Wall
208 GPM @ 2.6 fps 192 GPM @ 1.2 fps 136 GPM @ 1.9 fps 88 GPM @ 1.0 fps N.A. 172 GPM @ 1.0 fps
HYDRAULIC SYSTEM SPECIFICATIONS (continued)
SPECIAL NOTE ON CHANNEL DRAINS TO BUILDER, INSTALLER, PLAN CHECKER AND/OR INSPECTOR!
INSTALLATION LAYOUTS
A. See g. 1-5 on pages 7-9 for installation layout with manufactured sump.
B. See g. 6-7 on pages 9-10 for installation layout without sump (eld-fabricated sump).
C. Requires phillips screwdriver. Hand tighten only. Do not use electrical or air drills.
D.
SPECIAL NOTE
: USE ONLY PVC TO ABS (transitional glue) for cementing to ABS sump.
Do not use fast set, clear or “hot” blue glues.
E. Measure from underside of high point of the cover to the top of pipe(s) to determine proper sump depth.
F.
SPECIAL NOTE
: When installing vinyl/berglass versions, add a exible adhesive to fasteners and holes for extra leak
and tamper proong.