Owner's manual

INSTALLATION LAYOUTS
A. Requires Phillips screw driver. Hand tighten only. Do not use electrical or air drills.
B. See Fig. 1 for installation layout with manufactured sump
C. See Fig. 2 for installation layout without manufactured sump (Field-fabricated sump)
D. Measure from underside of high point of the cover to the top of pipe(s) to determine proper sump depth.
E. Top of all suction outlets shall not exceed 2" above pool oor or wall.
For additional information on proper drain installation refer to The Association of Pool & Spa Professionals
ANSI/APSP-7 Standard and the US Consumer Product Safety Commission Guidelines for Entrapment Hazard.
"A"
"B"
3/8" MIN. HT.
2" MAX. HT.
FROM FLOOR/WALL
FIELD FABRICATED
SUMP INSTALLATION
(SINGLE OR DUAL PORT)
INTERIOR
POOL FINISH
SHOTCRETE / GUNITE
HYDRO STATIC
RELIEF VALVE
OR 2" PLUG
COLLECTION TUBE
EARTH
GRAVEL
NOTE: WHEN NOT USING A RELIEF
VALVE, THE BOTTOM AREA
OF THE SUMP CAN BE USED
FOR A 2ND PLUMBING LINE
TO MAINTRUNK LINE WITH
SINGLE PUMP SYSTEM.
IDEAL HT. LINE
(ı# 1/4")
ANTI-ENTRAPMENT
SUCTION COVER
FRAME / MUD-RING
IMPORTANT
• AtIAPMOandUL(nationally recognized testing
labs), all AquaStar suction outlet covers have been
tested with 3" deep sumps (unless otherwise
indicated).
• “Aand/or“B”should
be a min. 3" to bottom of cover.
(except:
SUN18HPHxxx, WAV18xxx, P18xxx, 18MFxxx- 6",
WAV24xxx, P24xxx and 24xxx - 12",
A8Rxxx at 140 GPM-Floor / 84 GPM-Wall and
A10RCFRxxx - Sumpless)
• SecondLinecanbeonbottomarea.
• SingleorMultipledrainuse.
• Models:10AVRxxx, 10AVxxx, 8AVxxx, LP8AVxxx,
WAV9xxx, WAV12xxx, P9xxx, P12xxx, P18xxx, P24xxx
WAV24xxx, 24xxx, RFS9xxx, RFS12xxx,
WAV18xxx, 1216xxx, 914xxx, A8Rxxx, SUN18HPHxxx,
A10RCFRxxx, 8FUWxxx, 10LTxxx, 10LTDxxx, 8MFxxx,
R8MFxxx, 9MFxxx, R9MFxxx, 10MFxxx, 12MFxxx,
R12MFxxx, 18MFxxx
FIELD FABRICATED SUMP INSTALLATION (SINGLE OR DUAL PORT)
g. 2
3/8" MIN. HT.
2" MAX. HT.
FROM FLOOR/WALL
COLLECTION TUBE
NOTE: WHEN NOT USING AS RELIEF
PORT, CAN BE UTILIZED
AS 2ND PLUMBING LINE TO
MAINTRUNK LINE WITH
SINGLE PUMP SYSTEM.
MAX. BRANCH & MAIN LINE
SUCTIONS NOT TO EXCEED
3 FPS & 6 FPS VELOCITIES,
RESPECTIVELY.
MANUFACTURED
SUMP INSTALLATION
(DUAL PORT)
INTERIOR
POOL FINISH
SHOTCRETE / GUNITE
EARTH
GRAVEL
IDEAL HT. LINE
(ı# 1/4")
ANTI-ENTRAPMENT
SUCTION COVER
FRAME / MUD-RING
SUMP
HYDRO STATIC
RELIEF VALVE
OR
2" PLUG
MANUFACTURED SUMP INSTALLATION (DUAL PORT)
IMPORTANT
• Single or Multiple drain use.
• Models:SB,DD(A),orDDSB (B) (SB = Std Sump Bucket,
DD (A) = Deep Sump/Frame, DDSB (B)= Deep Sump
Bucket) with 10AVRxxx, 10AVxxx, 10LTxxx, 10LTDxxx,
8HPxxx, A8xxx, 8AVxxx, LP8AVxxx, WAV9xxx, WAV12xxx,
SUN9xxx, SUN12xxx, 1216xxx, R1216xxx, 914xxx,
R914xxx, A8Rxxx, 8FUWxxx, P9xxx, P12xxx, 8MFxxx,
R8MFxxx, 9MFxxx, R9MFxxx, 10MFxxx, 12MFxxx,
R12MFxxx, 18MFxxx
• NOTE:8"roundSBavailablein
3 styles: (6" Deep)
– Regular collar (frame) with side/bottom ports
– Adjustable collar (frame) (AC) with side/bottom ports
– Vinyl/berglass (V) with side/bottom ports
• NOTE:9"and12"squareand10"roundDDSB(B,D,F)
available in 3 styles: (12" Deep)
– Regular Collar (frame) with 2 - 2 1/2" & 2" ports on
bottom only (No Side Port) (B)
– Regular Collar (frame) with 1 - 4" port on bottom only
(No Side Port) (D)
– Regular Collar (frame) with 1 - 6" port on bottom only
(No Side Port) (F)
g. 1
P 877-768-2717 F 877-276-POOL info@aquastarpoolproducts.com www.aquastarpoolproducts.com
Rev 022514