Specification
NSF/ANSI 42
Influent
Challenge
Concentration
Reduction
requirement
Overall %
Reduction
Results
Chlorine Reduction,
Free Available
2.0 ± 10% mg/L 50% >97.4% Pass
Chloramine Reduction,
Free Available
2.0 ± 10% mg/L 50% >97.4% Pass
Particulate Reduction at least 10,000
particles/mL
85% >99.9% Pass
NSF/ANSI 53
Influent
Challenge
Concentration
Reduction
requirement
Overall %
Reduction
Results
Cyst Live Cryptosporidium
& Giardia
min 50,000/L 99.95% >99.99% Pass
Mercury Reduction
pH 8.5
0.006 ± 10%
mg/L
<2 ug/L >96.6% Pass
Mercury Reduction
pH 6.5
0.006 ± 10%
mg/L
<2 ug/L >96.6% Pass
Lead Reduction pH 6.5 .15 ± 10% mg/L <10 ug/L >99.3% Pass
Lead Reduction pH 8.5 .15 ± 10% mg/L <10 ug/L >99.3% Pass
MTBE Reduction .15 ± 20% mg/L <5 ug/L 81.8% Pass
Turbidity 11 ± 1 NTU <0.5 NTU 99.0% Pass
VOC Surrogate Test 300 ± 30 μg/L 95% 99.4% Pass
Asbestos Reduction 107 to 108
fibers/L; fibers
greater than 10
μm in length
99% >99% Pass
We have also tested this system’s ability to maintain healthy minerals (not as a
part of any NSF/ANSI standard):
Healthy Minerals Results
Calcium Tested to maintain levels
Potassium Tested to maintain levels
Magnesium Tested to maintain levels
Organic chemicals included by surrogate testing
VOCs
(by surrogate testing using
chloroform)
Drinking water
regulatory level
(MCL/MAC) mg/L
Influent/
Unfiltered
Euent/
Filtered
Percent
Reduction
alachlor 0.002 0.050 0.001 >98%
atrazine 0.003 0.100 0.003 >97%
benzene 0.005 0.081 0.001 >99%
carbofuran 0.04 0.190 0.001 >99%
carbon tetrachloride 0.005 0.078 0.0018 98%
chlorobenzene 0.1 0.077 0.001 >99%
chloropicrin — 0.015 0.0002 99%
2,4-D 0.07 0.110 0.0017 98%
dibromochloropropane
(DBCP)
0.0002 0.052 0.00002 >99%
o-dichlorobenzene 0.6 0.080 0.001 >99%
p-dichlorobenzene 0.075 0.040 0.001 >98%
1,2-dichloroethane 0.005 0.088 0.0048 95%
1,1-dichloroethylene 0.007 0.083 0.001 >99%
cis-1,2-dichloroethylene 0.07 0.170 0.0005 >99%
trans-1,2-dichloroethylene 0.1 0.086 0.001 >99%
1,2-dichloropropane 0.005 0.080 0.001 >99%
cis-1,3-dichloropropylene — 0.079 0.001 >99%
dinoseb 0.007 0.170 0.0002 99%
endrin 0.002 0.053 0.00059 99%
ethylbenzene 0.7 0.088 0.001 >99%
ethylene dibromide (EDB) 0.00005 0.044 0.00002 >99%
haloacetonitriles (HAN)
Bromochloroacetontrile — 0.022 0.0005 98%
Dibromoacetontrile — 0.024 0.0006 98%
Dichloroacetontrile — 0.0096 0.0002 98%
Trichloroacetontrile — 0.015 0.0003 98%
haloketones (HK)
1,1-dichloro-2-propanone — 0.0072 0.0001 99%
1,1,1-trichloro-2-propanone — 0.0082 0.0003 96%
heptachlor (H-34, Heptox) 0.0004 0.025 0.00001 >99%
heptachlor epoxide 0.0002 0.0107 0.0002 98%
hexachlorobutadiene — 0.044 0.001 >98%
hexachlorocyclopentadiene 0.05 0.060 0.000002 >99%
lindane 0.0002 0.055 0.00001 >99%
methoxychlor 0.04 0.050 0.0001 >99%
pentachlorophenol 0.001 0.096 0.001 >99%
simazine 0.004 0.120 0.004 >97%
styrene 0.1 0.150 0.0005 >99%
1,1,2,2-tetrachloroethane — 0.081 0.001 >99%
tetrachloroethylene 0.005 0.081 0.001 >99%
toluene 1 0.078 0.001 >99%
2,4,5-TP (silvex) 0.05 0.270 0.0016 99%
tribromoacetic acid — 0.042 0.001 >98%
1,2,4-trichlorobenzene 0.07 0.160 0.0005 >99%
1,1,1-trichloroethane 0.2 0.084 0.0046 95%
1,1,2-trichloroethane 0.005 0.150 0.0005 >99%
trichloroethylene 0.005 0.180 0.0010 >99%
Trihalomethanes (THMs) Influent/
Unfiltered
Euent/
Filtered
Percent
Reduction
Bromodichloromethane
(THM)
0.080 0.300 0.015 95%
Bromoform (THM)
Chloroform (THM)
Chlorodibromomethane
(THM)
Xylenes (total) 10 0.070 0.001 >99%
Not all water will contain contaminants listed.
Testing was performed under standard laboratory conditions, actual per-
formance may vary. Filter usage must comply with all state and local laws.
Filter is only to be used with cold water. Systems certified for cyst reduc-
tion may be used on disinfected waters that may contain filterable cysts.
See owner’s manual for general installation conditions and needs as well
as manufacturer’s limited warranty.
Do not use with water that is microbiologically unsafe or of unknown
water quality without adequate disinfection before or after the system.
Testing Performed under NSF/ANSI Standards 42 and 53 and in accordance with the California Department of Health Services Drinking Water Treat-
ment Device Program. This system has been tested according to NSF/ANSI 42 & 53 for reduction of the substances listed below. The concentration of the
indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system,
as specified in NSF/ANSI 42 & 53.
Performance Data for the Aquasana Drinking Water Filter models AQ-4000, AQ-4600 & AQ-4601
Replacement Operating pressure range Rated capacity Operating temp range Rated flow
AQ-4035 20–80 psi 450 gallons 40–90° F 0.5 gpm
Manufactured by Aquasana, Inc. · aquasana.com
6310 Midway Road · Haltom City, Texas 76117 · 866-662-6885
System tested and certified by NSF International
against NSF/ANSI Standard 42 and 53 for
the reduction of the claims specified on the
Performance Data Sheet and at www.nsf.org.
aq4000,4600,4601_DATAnsf_20130528