Pre-Planning Delivery Guide Need Assistance? Call 1-888-768-6772
Pre-Delivery Spa Delivery Preparation Your spa delivery will arrive CURBSIDE at the specified delivery address you provided at the time of your purchase. You will need to make prior arrangements for assistance in moving your spa into your desired spa location. If your spa location will be more than 10 feet from an existing electrical outlet that is ready and dedicated for spa use, you may also need to hire a professional electrician to establish those electrical connections.
Example of the AquaRest Curbside Delivery Instructions and Agreement located at our website, AquaRestSpas.com/Owners Curbside Delivery Instructions & Agreement Need Assistance? Call 1-888-768-6772 Please read instructions carefully to experience a smooth spa delivery. Please read AquaRest Spas Pre-Delivery Guide for details on site preparation for your new spa. All listed requirements must be met prior to delivery of your spa.
Pre-Delivery Spa Location Checklist (more details on following pages): o Is permitting required for construction, electrical or barriers? o Is the support surface adequate to support the weight of the spa? o Is the support surface adequate to handle water overflow? o Are there considerations for limiting access by children? o Are there overhead electrical lines? o Will the electrical cord reach an outlet? o Is the electrical outlet dedicated for the spa use only? o Is there adequate room to a
Site Selection Before proceeding, please read the ‘Important Safety Instructions’ at the beginning of the owner’s manual, available on our website, AquaRestSpas.com/Owners. 1. Electrical Connection. Installing your new Dream Maker Spa couldn’t be simpler. After filling your spa, just plug it in to any standard 120v / 15 amp outlet for power.* Do not use an extension cord. If you prefer, our models can be hardwired by a certified electrician.
Site Selection Provide a solid load-bearing site: CAUTION: Your spa must be installed on a level, flat, solid load-bearing surface. Do not locate the spa on a surface that can be damaged or altered by water. • The site must provide a solid foundation with a minimum load bearing capacity of 117 pounds per square foot (572 kgs per square meter). • Concrete slabs and decks must be designed to support this weight.
Electrical Requirements for 120V 15AMP • Locate your spa so that the GFCI plug and cord will reach a dedicated 120V outlet, but not closer than 5 feet (1.5 meters). A dedicated outlet is one that does not have other electrical devices operating on the same circuit. This can be checked by turning off the circuit breaker that supplies the intended outlet and verifying that no other electrical devices no longer work, such as a refrigerator, dishwasher, washing machine, coffee maker, hair dryer, etc.
Electrical Requirements for 240V* • 240V electrical connections must be completed by a Certified Licensed Electrician. A GFCI AND A DISCONNECT SWITCH ARE REQUIRED: The National Electrical Code requires that spas connected to 240V circuits be equipped with a GFCI and Disconnect Switch. See National Electrical Code Articles 680-12 and 680-42. • ISOLATED, DEDICATED 240V, 30 OR 50 AMP CIRCUITS ARE REQUIRED.
Congratulations! You are now ready to start Living the Spa Life. Welcome to the AquaRest Family! Customer Service is here to serve you and ensure the best possible experience.