User Manual
Features
• LowMaintenance-Reduced
cleaningrequirements
• Smallsizeenablesconvenient
installationandservice.
• O-ringsealsusedonallver-
sionsforhighon-streamreliability
• Plasticglandfittingallowsre-
movalandreplacementwithouttools
• AutomaticTemperatureCom-
pensation
TheAM3455sensorsareweldedtoblindflangesandcanbe
insertedinto standard tee fittingsin sanitary systemsusing
LadishorTri-Cloverfittings.
Wettedmaterialsofconstructionare316Lstainlesssteeland
Teflon, with double redundant EPDM o-rings. The process
side or-ring is the only one in contact with the stream, al-
lowingthebacko-ringtomaintainreliablesealing,freefrom
chemical attack. Temperature compensation elements are
pottedinthebodyitself.Leadsare10’standard.
ProcessconnectionsareTri-Clampsanitaryflanges ofcus-
tomerspecifiedsize.Theinsertiondepthcanbemodifiedon
requesttoobtainproperpositioninginaspecificinstallation.
Thesensorisbuiltforcleanin-placeservice,eitherstreamor
sterilizingchemicals.AllwettedmaterialsareFDAcompliant
andUSPClassVIisavailable.
Description
100SchoolStreet
Andover,MA01810
978-749-9949
Tollfree-855-747-7623
www.WaterAnalytics.net
Applications
• Dairy
• FoodandBeverage
• Allsanitaryapplications
• Highpuritywaterapplications
• PharmaceuticalApplications
• ReverseOsmosissystems
Aquametrix Model AM3455 Series
Stainless Steel Sanitary Conductivity Sensors
GreatLakes
Replacement
by
Water Analytics
Aqua
Metrix
by
Water Analytics
Aqua
Metrix