Specifications
COMMISSIONING 
53 
OUTLET TEMPERATURE COMPENSATION ADJUSTMENT – CG20-50 SERIES 
The  maximum  outlet  temperature  of  a  CG20-50 series  water  heater  may  be  adjusted  to  compensate  for 
temperature losses in the pipe work between the water heater outlet and sanitary fixtures. 
 Warnings 
  After  adjustment,  the  water  temperature  from  the  first  tap in  the  hot  water  pipe  work  after  the  water 
heater used for personal hygiene purposes, such as in a bathroom or ensuite, MUST NOT exceed: 
  48°C if a temperature controller is connected to the water heater, or 
  50°C if a temperature controller is not connected to the water heater. 
  If there is a tap, such as a kitchen or laundry tap, in the hot water pipe work between the water heater 
and the first tap used for personal hygiene purposes, then it is possible for a water temperature to be 
delivered from that tap of up to 3°C to 5°C higher than the setting shown on the controller. 
It  is  necessary  to  have  the  electrical  supply  to  the  water  heater  switched  on  during  stages  of  the  outlet 
temperature compensation adjustment procedure. 
 Warnings 
  The removal of the front panel will expose 240 volt wiring. Take care not to touch wiring terminals. The 
adjustment must be carried out by a qualified person. 
  This procedure will involve the adjustment of dip switches. Adjustment of a dip switch should only be 
made with an insulated tool. 
Before Commencing the Procedure 
This procedure cannot be conducted: 
  With a temperature controller connected to the water heater. 
  A  temperature  controller(s)  connected  to  the  water 
heater  must  be  disconnected  prior  to  the 
commencement of this procedure. 
Refer to “Disconnecting a Temperature Controller(s)” on 
page 53. 
Disconnecting a Temperature Controller(s) 
To disconnect the temperature controller(s): 
1.  Switch  off the  electrical  supply  at the  power  outlet  to  the 
water heater. 
2.  Unscrew and gently remove the  front panel  of the water 
heater. 
3.  Loosen the terminal screws to release the cable lugs. 
The two  remote controller terminals are  adjacent to each 
other and located at the top right of the printed circuit board 
(PCB),  to  the  right  of  the  label  marked  „REMOTE 
CONTROLLER TERMINAL‟. 
4.  Withdraw the cable lugs, ensuring they are well clear of the 
terminals. 