Specifications
COMMISSIONING 
51 
PRESET OUTLET TEMPERATURE SETTING 
The factory preset outlet temperature setting of the water heater is: 
  CG20-60 series  60°C 
  CG20-50 series  48°C 
If a temperature controller is connected to the water heater, this will override the preset outlet temperature 
setting and the maximum temperature setting will be: 
Maximum Outlet Temperature 
CG20-60 
series 
CG20-50 
series 
Kitchen controller connected 
60°C 
48°C 
Bathroom controller only connected 
50°C 
48°C 
It is usually not necessary to adjust the factory preset outlet temperature setting of the water heater, unless 
the  customer  has a  particular  requirement  for  this  to  be  done  or  it  is  to  be  installed  as  an  in-series  gas 
booster to a solar water heater. 
Refer to “To Check or Adjust  the Preset Outlet Temperature Setting” on page 52 to check or if required to 
adjust the preset outlet temperature setting of the water heater. 
Gas Booster for a Solar Water Heater 
Note: AS 3498 requires that a water heater provides the means to inhibit the growth of Legionella bacteria in 
potable water. When this water heater is used as an in-series booster for a solar water heater it can satisfy 
this AS 3498 requirement provided it is energised, the booster preset outlet temperature setting is 70°C, and 
that a remote temperature controller is not used. 
It will be necessary to check and if required to adjust the preset outlet temperature setting of the continuous 
flow water heater when: 
  it is installed as an in-series gas booster to a solar water heater 
  it is an existing continuous flow water heater and a solar water heater is then installed. 
Notes: 
  Consideration  must  be  given  to  the delivery temperature  to  any  ablution  and  public  areas  such  as  a 
bathroom, ensuite or public amenities. Refer to “Hot Water Delivery” on page 29 and to “Schematics of 
Two Temperature Zones Using A Temperature Limiting Device” on page 30. 
  The CG20-50 model water heaters, marked “THIS APPLIANCE DELIVERS WATER NOT EXCEEDING 
50°C IN ACCORDANCE WITH AS 3498” on the front panel, must not be installed as an in-series gas 
booster to a solar water heater, as water temperature greater than 50°C can be delivered from the water 
heater contravening its compliance to AS 3498. 