Specifications
ABOUT YOUR WATER HEATER 
5 
MAINS PRESSURE 
The water heater is designed for direct connection to the mains water supply. If the mains supply pressure in 
your area  exceeds  that  shown on page 28,  a  pressure  limiting valve must  be  fitted. The supply pressure 
should be greater than 140 kPa for the rated flow and performance to be achieved. 
HOW HOT SHOULD THE WATER BE? 
The  water  heater  may  be  installed  with  one  or  more  user 
adjustable  temperature  controllers,  which  allow  you  to 
choose  the  most  suitable  temperature  for  your  hot  water 
needs (refer to “Temperature Control” on page 11). 
If a controller is not installed, the water heater heats the 
water  to  the  preset  outlet  temperature  setting.  The  factory 
preset outlet temperature setting is: 
  CG20-60 series  60°C 
  CG20-50 series  48°C 
Note:  The  preset  outlet  temperature  setting  of  this  water 
heater  cannot  be  adjusted  by  the  householder.  The  setting 
can only be adjusted by the installer or Aquamax Service. 
Note:  AS 3498 requires  that a  water  heater  provides  the 
means to inhibit the growth of Legionella bacteria in potable 
water. When this water heater is used as an in-series booster 
for  a  solar  water  heater  it  can  satisfy  this  AS 3498 
requirement provided it is energised, the booster preset outlet 
temperature  setting is  70°C, and  that a  remote temperature 
controller is not used. 
  Warning: Temperature controllers must not be  fitted to  this water heater (CG20-60  model) if  it is 
installed as an in-series gas booster with a solar water heater system because water at a temperature much 
higher than the controller setting can be delivered. If a solar water heater has been installed to an existing 
water heater installation, then all controllers must be disconnected and removed. 
If  this  water  heater  is  installed  as  part  of  a  solar  water  heater  system,  the  system can  deliver  water  at 
temperatures from 58°C up to 80°C with an Aquamax pumped direct solar water heater. 
HOTTER WATER INCREASES THE RISK OF SCALD INJURY 
This water heater can deliver water at temperatures which can cause scalding. Check the water temperature 
before  use,  such  as when  entering  a  shower  or  filling  a  bath  or  basin,  to  ensure  it  is  suitable  for  the 
application and will not cause scald injury. 
We recommend and it may be required by regulations that an approved temperature limiting device be fitted 
into the hot water piping to the bathroom and ensuite when a CG20-60 model water heater is installed. This 
will keep the  water temperature  below  50°C  at the  bathroom and ensuite. The  risk of scald  injury  will be 
reduced and if no controllers are installed or if a Kitchen controller is installed, still allow hotter water to the 
kitchen and laundry. 
A CG20-50 model water heater will not deliver temperatures exceeding 50°C, in accordance with AS 3498. 
There is no requirement in AS/NZS 3500.4 to fit a temperature limiting device if this water heater is installed 
in other than an early childhood centre, school, nursing home or a facility for young, aged, sick or disabled 
people. 
maximum Kitchen controller 
temperature setting 
CG20-60 series 
maximum recommended supply 
temperature to bathrooms and 
ensuites. 
maximum Bathroom controller 
temperature setting 
CG20-60 series 
maximum Kitchen and Bathroom 
controller temperature setting 
CG20-50 series 
minimum Kitchen and Bathroom 
controller temperature setting 