Specifications
INSTALLATION – CONTROLLERS 
43 
BATHROOM1 AND BATHROOM2 CONTROLLERS 
If only one Bathroom controller is to be installed, the Bathroom1 Controller (PN AQ3264105) must be used. If 
two Bathroom controllers are to be installed, one must be a Bathroom1 controller and the other must be a 
Bathroom2 controller (PN AQ3264106). 
They have a minimum temperature setting of 37°C and a maximum temperature setting of: 
  CG20-60 series  50°C 
  CG20-50 series  48°C 
The method of installation for the Bathroom1 and Bathroom2 controllers is identical. 
Choose a suitable location for each Bathroom controller, away from water, heat, and sunlight. The Bathroom 
controllers are supplied with a 250 mm length of wire with connectors to mate with the Bathroom controller 
cable. 
Notes: 
  It is not recommended to have exposed wiring in a bathroom. 
  Do not apply sealant to the controller cable. 
Bathroom1 and Bathroom2 Controller Components 
screw x 2 
controller screw 
base plate 
foam packing 
Bathroom controller 