Gas Booster for a Solar Water Heater 
The temperature limiting device used with a CG20-60 model in-series gas booster as part of a solar water 
heater installation must have the additional capability of receiving a hot water supply temperature of up to 
99°C if the solar water heater does not have an over temperature protection system to limit the water to no 
greater than 90°C. 
  Warning: Temperature controllers  must not be  fitted to  this water  heater (CG20-60  model) if  it  is 
installed as an in-series gas booster with a solar water heater because water at a temperature much higher 
than the controller setting can be delivered. If a solar water heater is installed to an existing water heater 
installation, then all controllers must be disconnected and removed. 
Where a temperature limiting device is installed adjacent to the in-series gas booster, the cold water line to 
the temperature limiting device can be branched off the cold water line either before or  after the isolation 
valve and pressure limiting valve to the solar storage tank, but it MUST BE before the non return valve prior 
to an open circuit direct system. If an expansion control valve is required, it must always be installed after the 
non return valve and be the last valve prior to the solar storage tank. 
 Warning: A non return valve MUST BE installed on the cold water line to the solar storage tank AFTER 
the  cold  water  branch  to  a  temperature  limiting  device  prior  to an  open  circuit  direct  system.  Due  to  the 
higher water temperatures generated under certain conditions in the solar collectors of an open circuit direct 
solar  water  heater,  an  additional  effective  back-flow  prevention  device  also  should  be  used  as  an  extra 
safeguard. Valve manufacturer RMC recommends Dual Check Valve model N7150, as being suitable for this 
application. 
If a combination isolation valve and non return valve (duo or trio valve) is installed on the cold water line to 
an open circuit direct solar water heater and the cold water line to the temperature limiting device branches 
off after this valve, then a second non return valve must be installed between the cold water branch and the 
solar  storage  tank.  Due  to  the  higher  water temperatures  generated  under  certain conditions  in  the  solar 
collectors  of  an  open  circuit  direct  pumped  solar  water  heater,  an  effective  back-flow  prevention  device 
should  be  used  as  the  second  non  return  valve  as  an  extra  safeguard.  Valve  manufacturer  RMC 
recommends Dual Check Valve model N7150, as being suitable for this application. 
If a pressure limiting valve is installed on the cold water line to the solar water heater and the cold water line 
to a  temperature limiting device branches off before  this valve or from another  cold water line in the 
premises,  then  a  pressure  limiting  valve  of  an  equal  pressure  setting  may  be  required  prior  to  the 
temperature limiting device. 