Specifications
26 
INSTALLATION – WATER HEATER 
THIS WATER HEATER IS FOR OUTDOOR INSTALLATION ONLY. 
THIS WATER HEATER IS NOT SUITABLE FOR POOL HEATING. 
Check the water heater is suitable for the gas type available. 
(refer to the rating label on the water heater) 
INSTALLATION STANDARDS 
The water heater must be installed: 
  by a qualified person, and 
  in accordance with the installation instructions, and 
  in compliance  with  Standards AS/NZS 3500.4,  AS 5601  or AS/NZS 5601.1,  as  applicable  under  local 
regulations, and all local codes and regulatory authority requirements. 
All packaging must be removed from the water heater, including the packing piece in the flue outlet, prior to 
its installation. 
WATER HEATER APPLICATION 
This water heater is designed for use in a single family domestic dwelling for the purpose of heating potable 
water. Its use in an application other than this may shorten its life. 
If this water heater is to be used where an uninterrupted hot water supply is necessary for the application or 
business,  then  there  should  be  redundancy  within  the  hot  water  system  design.  This  should  ensure  the 
continuity of hot water supply in the event that this water heater was to become inoperable for any reason. 
We recommend you provide advice to the system owner about their needs and building backup redundancy 
into the hot water supply system. 
The CG20-60 model water heaters may be installed as an in-series gas booster to a solar water heater. For 
information relating to the function and operation of the solar water heater, refer to the Owner‟s Guide and 
Installation Instructions supplied with the solar water heater. 
Note:  The  CG20-50  model  water  heaters  are  marked  “THIS  APPLIANCE  DELIVERS  WATER  NOT 
EXCEEDING 50°C IN ACCORDANCE WITH AS 3498” on the front panel. These models; 
  must not be installed as an in-series gas booster to a solar water heater, as water temperature greater 
than 50°C can be delivered from the water heater contravening its compliance to AS 3498. 
Note: AS 3498 requires that a water heater provides the means to inhibit the growth of Legionella bacteria in 
potable water. When this water heater is used as an in-series booster for a solar water heater it can satisfy 
this AS 3498 requirement provided it is energised, the booster preset outlet temperature setting is 70°C, and 
that a remote temperature controller is not used. 
WATER HEATER LOCATION 
The water heater should be installed close to the most frequently used outlet  and its position chosen with 
safety  and  service  in mind.  If  this  water  heater  is  part  of  a  solar  water  heater  system,  it should  also  be 
installed  close  to  the  solar  storage  tank.  Make  sure  people  (particularly  children)  will  not  touch  the  flue 
terminal. The flue terminal and air inlet must be clear of obstructions and shrubbery. 
Clearance must be allowed for servicing of the water heater. The water heater must be accessible without 
the use of a ladder or scaffold. Make sure the entire front panel can be removed for service. You must be 
able to read the information on the rating plate. Remember you may have to take the entire water heater out 
later for servicing. 