Full Product Manual
14
Operate Your Spa
Topside Control Panels
System Settings
When your spa is first actuated, it will go into Prim-
ing mode, indicated by “Pr.” The Priming mode will
last for less than 5 minutes (press a Temperature
button to skip Priming Mode) and then the spa will
begin to take temperature readings, followed by the
heater test cycle. After completed, the heater will
turn on, heat the spa and maintain the water tem-
perature in the Standard mode.
The start-up temperature is set at 100°F/37°C.
The last measured temperature is constantly dis-
played on the LCD. Note that the last measured
spa temperature displayed is current only when the
pump has been running for at least 2 minutes.
Maximum Temperature is set at 104ºF/40ºC
as required by UL/CSA.
Minimum temperature is 80ºF/26ºC.
Note: If the spa is currently in a heating or filtration
cycle the primary pump will only switch between high
and low. It cannot be turned off until the heating or fil-
tration cycle is completed.
Preset Filter Cycles
The first filter cycle
begins 6 minutes after
the spa is energized.
The second filter cycle begins 12 hours later. The
default filter time is 2 hours. Recommended setting
is F2.
Example: In a 12 hour period (1 cycle), a setting of F2
means 2 hours of filtration on, 10 hours of filtration off.
You may choose F2, F4, F6, F8 or c (continuous).
To program, press a temperature button, then “Jets”.
Press a temperature button to adjust. Press “Jets” to
exit.
Mode
Mode is changed by pressing a temperature button,
then pressing the “Light” button.
Standard Mode is programmed to maintain the
desired temperature.
Note that the last
measured spa temper-
ature displayed is current only when the pump has
been running for at least 2 minutes. “ST” will be dis-
played momentarily when you switch into Standard
Mode. The temperature is constantly displayed when
in Standard Mode. This is the best mode to use dur-
ing COLD weather.
Economy Mode heats the spa to the set temper-
ature only during fil-
ter cycles or if the
temperature falls to 20
degrees below set temperature. “EC” will display
solid when temperature is not current, and will al-
ternate with temperature when temperature is cur-
rent. This is the best mode to use during WARM
weather.
Sleep Mode heats the spa to the set temperature
only during filtration
cycles. “SL” will display
solid when tempera-
ture is not current, and will alternate with tempera-
ture when temperature is current, but only within
20 degrees of your set temperature.
Freeze Protection
If the temperature sensors detect a drop to below
44°F/6.7°C within the heater, the pumps will auto-
matically activate to provide freeze protection. The
equipment stays on until 4 minutes after the sensors
detect that the spa temperature has risen to
45°F/7.2°C or higher.
ST
Ec
SL
F 2
STD
Ecn
SLP
FIL