Specifications
9
Set Day and Time
Wednesday 10:37P
+
>
>
Adjust the current day of the week
Move to hours setting
Set Day and Time
10:37P
+
>
>
Adjust the current day of the week
Move to hours setting
Set Day and Time
Set Day and Time
+
+
>
>
>
>
Adjust the current hour (including AM/PM, if applicable)
Adjust the current minute
Move to minutes setting
Move to previous/next menu item
37
Wednesday
Wednesday
10: P
Use this function to set the current day of the week and time. These values are used for all
the automatic timeclock functions of the Aqua Logic and are also displayed as part of the
default menu.
The Aqua Logic is designed to keep the clock running during power outages lasting less
than 7 days. If power has been off for longer than 7 days, then the time may have to be reset.
Display Light
On for 60 sec.
+
>
>
Toggle between Always On and On for 60 sec.
Move to previous/next menu item
This function controls the backlight on the display. If the “60 seconds” option is selected,
then the backlight will automatically turn off 60 seconds after the last key is pressed and will
stay off until next time a key is pressed.
Note that the Display Light selection only applies to the display keypad that you are currently
using. Other display/keypads will not be affected. In other words, you need to individually
set this option for each display/keypad in the system.
+
>
>
Beeper
Enabled
Toggle between Beeper Enabled (default) and Disabled
Move to previous/next menu item
When “Enabled”, the keypad will beep every time a key is pressed. If this is not desired,
select “Disabled”.
This function only applies to the display/keypad that you are currently using. You need to
set this option for each display/keypad in your system.
NOTE: This function is not supported on all display/keypads. If the “Enabled” selection is
not blinking, then the current software revision of that particular keypad/display does not
support the option and it will default to Beeper Enabled.
Teach Wireless
+ to start
Teach
Successful
Wireless
Teach
NOT Successful
Wireless
Teach Wireless
Base NOT Found
Press and hold
wireless button
Push to start process
Move to previous/next
menu item
Move to previous/next
menu item
Move to previous/next
menu item
Move to previous/next
menu item
Press any button on wireless remote
+
>
>
>
>
>
>
>
>
This menu will only appear if a wireless base station is connected to the Aqua Logic. Perform
this procedure each time a wireless remote control is added to the Aqua Logic system.
26
Gallons
Liters
(pool size in feet)
(pool size in meters)
Rectangular
Round
Oval
Diameter x Diameter x
Average Depth x 5.9
Length x Width x
Average Depth x 6.7
Length x Width x
Average Depth x 7.5
Diameter x Diameter x
Average Depth x 785
Length x Width x
Average Depth x 893
Length x Width x
Average Depth x 1000
The pool’s chemistry must be balanced BEFORE activating the Aqua Logic’s optional chlorinator func-
tion. NOTE: If the pool does not have new water, add metal remover and non-copper based algaecide
to the pool, per manufacturer’s instructions. This ensures a quick, troublefree transfer to the Aqua Logic
system.
Salt (When using optional chlorinator function - requires AQL-CL chlorination kit)
Salt Level
Use the chart on the following page to determine how much salt in pounds or (Kgs) should be added to
reach the recommended levels. Use the equations below (measurements are in feet/gallons and meters/
liters) if pool size is unknown.
The operating salt level is between 2700-3400 PPM (parts per million) with 3200 PPM being optimal.
Before adding any salt, test the salt level. This is especially important for retrofit installation to older pools
where chlorine added to the pool over time has ended up as salt. If the level is low, determine the number
of gallons in the pool and add salt according to the chart below. A low salt level will reduce the efficiency
of the sanitization and result in low chlorine production. A high salt level can cause the Aqua Logic to stop
chlorinating. The salt in your pool/spa is constantly recycled and the loss of salt throughout the swimming
season should be minimal. This loss is due primarily to the addition of water because of splashing,
backwashing, or draining (because of rain). Salt is not lost due to evaporation.
Type of Salt to Use
It is important to use only sodium chloride (NaCl) salt that is greater than 99.0% pure. This can be found
at most pool stores in 40-80 lb. bags labeled “for use in swimming pools”. Alternatively, use common food
quality or water softener salt that is at least 99.0% pure. It is also acceptable to use water conditioning salt
pellets, however, it will take longer for them to dissolve. Do not use rock salt, or salt with more than 1%
of yellow prussiate of soda, salt with anti-caking additives, or iodized salt.
How to Add Salt
For new plaster pools, wait 10-14 days before adding salt to allow the plaster to cure. Turn the circulating
pump on and add salt directly into the pool. Brush the salt around to speed up the dissolving process—do
not allow salt to pile up on the bottom of the pool. Run the filter pump for 24 hours with the suction coming
from the main drain (use pool vacuum if there is no main drain) to allow the salt to evenly disperse through-
out the pool. The salt display may take 24 hours to respond to the change in salt concentration.
Always check stabilizer (cyanuric acid), when checking salt. These levels will most likely decline together.
Use the chart on page 28 to determine how much stabilizer must be added to raise the level to 80 ppm.