Specifications

13
This menu will appear only if Valve3 is configured for timeclock. The valve will rotate on and
off at the designated times. There is no manual override. If the Valve3 relay is on during the
programmed off time, it may be because of freeze protection.
Super Chlorinate
24 hours
+
>
>
Adjust Superchlorination period (1 - 96 hours)
Move to previous/next menu item
Larger pools or when you have an unusually high bather load, a large amount of rain, a
cloudy water condition, or any other condition that requires a large amount of chlorine to be
introduced to the pool, may require more hours of Superchlorination. Smaller pools require
less hours of Superchlorination.
Configuration Menu
The Aqua Logic MUST BE CONFIGURED before attempting to operate. Configuration information is
entered at the keypad and “tells” the Aqua Logic what equipment is connected and how each should be
controlled.
!
CAUTION: When changing an existing configuration, it is important to understand how
the pool system operates and what specific equipment is connected to each output. Incor-
rect settings in the configuration menu could lead to damaged equipment and improper
operation of the pool system.
Accessing the Configuration Menu
Configuring the Aqua Logic requires that you navigate through the Configuration Menu and input various
information. For more detailed information about using the Aqua Logic menu system, refer to the Opera-
tion Manual.
To access the Configuration Menu
Configuration
Menu-Unlocked
Configuration
Menu-Locked
Press repeatedly until “Configuration Menu” is displayed
Move to configuration menu items
Press BOTH buttons SIMULTANEOUSLY for 5 seconds to unlock
Menu
>
>
>
>
NOTE: The configuration menu automatically “locks” after 2 minutes of no buttons being
pressed to prevent unauthorized people from changing the control logic inadvertently and
possibly damaging the pool equipment or causing a “call back” to fix the configuration.
22
Quick “How To” Guide
Operate the Spa—Manually
1. Press the “Pool/Spa” button to go to “spa-only” operation (right LED illuminated). In some
cases, this may take more than one press of the button.
2. If the filter pump is not already on, press the “FILTER” button to turn it on.
3. If the spa is below the desired temperature, the heater will turn on automatically when the filter
pump is on and the valves are in the spa-only position. If you have not already set the desired
temperature for the spa, see “Set Heater Temperature” below
4. If the spa has a separate jet pump and or blower, determine if the jet pump/blower is con-
trolled by Aux1 or Aux2 (it should be marked on the label inside the door). Then press the
appropriate button to turn on the jets/blower.
Operate the Spa—Automatically
1. Press the “MENU” button repeatedly until “Timers Menu” is displayed
2. Press the “>” button repeatedly until the “Spa—all” or “Spa—wkend” is displayed.
3. Use the “+” and “-“ buttons to set the desired start time, then press “>” to switch to the off
time. Use the “+” and “-“ buttons to adjust the off time. If you are setting the “weekend”
timeclock, press “>” to go to the “weekday” settings.
Note: During the programmed spa time, the valves will automatically switch to the
“spa-only” position, the filter pump will turn on, and, if the spa is not up to the desired
temperature, the heater will start. This operation is the highest priority and will take
precedence over other automatically programmed operations. At the end of the spa
period, the Aqua Logic will return to its normally programmed operation state.
Set the Heater Temperature (or turn heater permanently off)
1. Press the “MENU” button repeatedly until “Settings Menu” is displayed
2. Press the “>” button repeatedly until the “Spa Heater1” or “Pool Heater1” is displayed.
3. Press the “+” or “-“ buttons repeatedly to adjust the temperature. If you adjust the tempera-
ture below 65ºF or above 104°F the display will indicate “off” and the heater will not operate
regardless of temperature.
Note: Separate temperatures for the pool and spa must be set. If the valves are in the
pool-only or spa spillover positions, then the heater will use the pool setting. If the
valves are in the spa-only position then the heater will operate according to the spa
setting.
Set the Chlorinator Output
1. Press the “MENU” button repeatedly until “Settings Menu” is displayed
2. Press the “>” button repeatedly until the “Spa Chlorinator” or “Pool Chlorinator” is displayed.
3. Press the “+” or “-“ buttons repeatedly to adjust the setting. If you adjust the setting to 0% the
chlorinator will be off all the time
Set Day and Time
Wednesday 10:37P
+
>
>
Adjust time setting
Move between start and stop times & to previous/next menu item
Valve3-all
8:30A to 4:00P
+
>
>
Adjust time s
Valve3-wkend
8:30A to 4:00P
Valve3-wkday
8:30A to 4:00P
+
+
>
>
>
>
Adjust time setting
Adjust time setting
Move between start and stop times & to previous/next menu item
Move between start and stop times & to previous/next menu item
or