Specifications

1817
desired temperature is in the “Settings Menu”. If applicable, the homeowner will be prompted
to enter separate pool and spa desired temperature settings. Depending on the position of
the pool/spa suction valve, the proper temperature setting will be used.
Solar Extend
If “Enabled”, the filter extend logic keeps the filter pump running beyond the normal turn-off
time if solar heat is still available. When solar heat is no longer available, both the solar
valve/pump and filter pump will turn off simultaneously. Solar extend will NOT cause the
filter pump to turn on, it will only delay the turn off time when solar is operating.
Solar Priority
If both “Solar Control” and “Heater Control” are enabled, the Solar Priority feature will keep
the conventional heater off whenever solar heat is available. This provides the most cost
effective way of heating the pool. When solar heat is not available, the conventional heater
will operate normally.
Lights Interlock
Disabled
Lights Freeze
Disabled
+
+
>
>
>
>
Toggle between Enabled and Disabled (default) Lights Interlock
Toggle between
Enabled and Disabled (default) Lights Freeze Protection
Move to next menu item
Move to previous/next configuration menu
Lights Config.
+ to view/change
Lights Function
Manual On/Off
Lights Relay
Standard
+
+
+
>
>
>
>
>
>
Push to access Lights options
Rotates between
options, and Super Chlorinate
Manual On/Off (default), Countdown Timer, Timeclock,
Solar, Low speed of a 2-speed pump
Toggle between Standard (default) and Dimmer
Move to previous/next configuration menu item
Move to next menu item
Move to next menu item or previous/next configuration menu
for all functions except solar and
low speed of 2-speed filter pump and dimmer
for all functions except
low speed of 2-speed filter pump
for manual on/off, countdown
timer and timeclock functions
Lights Function
Although designated as the “Lights” output, the function of the lights relay is similar to the
aux1 and aux2 relays. If pool lights are wired to the lights relay, some options including Solar
function, Low Speed of a 2-Speed Filter Pump, Lights Interlock and Lights Freeze Protection
will not be necessary and should be disabled. If no pool lights are used, the lights relay can
be used to control other pool devices that may require these options. The function of each
option is shown below.
Manual On/Off—the lights relay will alternate between turning on and off when the LIGHTS
button is pressed. There is no automatic control logic.
Countdown Timer—the lights relay will turn on when the LIGHTS button is pressed. The
lights relay will turn off automatically after a programmed time (see Timers Menu in Operation
Manual). The LIGHTS button can also be used to turn the output off.
Timeclock – the lights relay will turn-on and turn-off at the times set for the lights timeclock
in the Settings Menu (see Settings Menu in Operation Manual). The LIGHTS button can
also be used to turn the output on and off.
Solar – the lights relay can operate a solar booster pump which will turn on when the filter
pump is running and solar heat is available and the water is less than the desired temperature
setting. It is important to note that “Solar Control” must be enabled in the “Solar Config.”
menu for proper operation to occur.
Low Speed of a 2-speed Filter Pump – the Aqua Logic will turn on the lights relay whenever
the low speed operation of the filter pump is required. It is very important that the “2-speed”
filter pump option be selected under the “Filter Config.” Menu for proper operation.
Super Chlorinate – if “Chlorinator” is enabled, this option allows the user to start a Super
Chlorinate cycle when the Lights button is pressed, rather than using the Settings Menu.
Note that only one button can me assigned to this function.
Lights Relay
This feature allows the user to select either “Standard” (default) or “Dimmer” type relay for
the Lights output. The optional AQL-DIM dimmer kit must be installed if “Dimmer” is
desired. When “Dimmer” is selected, and the Lights output is manually turned on, the “+”
and “-” buttons adjust the level from 20% to 100% (default). The level is saved for the next
time the lights are turned from off to on.
Lights Interlock
If enabled, this feature will override the function (Manual On/Off, Countdown Timer,
Timeclock) selected above and turn the lights relay off when: filter pump is off, first 3
minutes of filter pump operation (allows the pump to prime and get water flowing), when the
pool/spa suction return valves are in any position other than “pool only”, or for the first 3
minutes after solar turns on (allows air in the solar panels to be purged). Interlock is not
available for solar, low speed filter pump, or dimmer.
Lights Freeze Protection
This function helps protect equipment that is wired to the lights relay against freeze damage.
If Freeze Protection is enabled and the AIR temperature sensor falls below the selected freeze
temperature threshold, the Aqua Logic will energize the lights relay. IMPORTANT: this only
enables operation of the lights relay during freeze--see the “Filter Pump Config.” menu to
enable freeze protection for the main circulation system. Freeze Protection is not available
for low speed filter pump or dimmer.
NOTE: The configuration parameters for the Aux2 output is the same as shown below for Aux1.
Aux1 Config.
+ to view/change
Aux1 Function
Manual On/Off
Aux1 Interlock
Disabled
Aux1 Freeze
Enabled
+
+
+
+
>
>
>
>
>
>
>
>
Push to access Aux1 options
Rotates between
options, and Super Chlorinate
Manual On/Off , Countdown Timer, Timeclock,
Solar, Low speed of a 2-speed pump
(default)
Toggle between Enabled and Disabled (default) Aux1 Interlock
Toggle between Enabled (default) and Disabled Aux1 Freeze
Move to previous/next configuration menu item
Move to next menu item
Move to next menu item
Move to previous/next configuration menu
Aux1 Relay
Standard
+
>
>
Toggle between Standard (default) and Dimmer
Move to next menu item or previous/next configuration menu
for all functions except
low speed of 2-speed filter pump
for manual on/off, countdown
timer and timeclock functions
for all functions except solar and
low speed of 2-speed filter pump and dimmer
!
WARNING: Do not use the Aqua Logic to control an automatic pool cover. Swim-
mers may become entrapped underneath the cover.
Aux1 Function
Manual On/Off (default)—the aux relay will alternate between turning on and off when the
aux button is pressed. There is no automatic control logic.
Countdown Timer – the aux relay will turn on when the AUX button is pressed and then will
turn off automatically after a programmed time (see Timers Menu, Operation Manual). The
AUX button can also be used to turn the output off.
Timeclock – the aux relay will turn-on and turn-off at the times set for the aux1 timeclock in
the Timers Menu. The AUX button can also be used to turn the output on and off.