Specifications

16
+
>
>
+
>
>
+
+
>
>
>
>
+
>
>
Heater1 Config.
+ to view/change
Heater1
Disabled
Heater1 Cooldown
Disabled
Heater1 Extend
Disabled
Push to access heater options
Toggle between Enabled and Disabled (default) Heater 1
Toggle between Enabled and Disabled (default) Heater 1 Cooldown
Toggle between Enabled and Disabled (default) Heater 1 Extend
Move to previous/next configuration menu
Move to next menu item or previous/next configuration menu
Move to next menu item
Move to previous/next configuration menu
if “Heater1” is enabled
if “Heater1” is enabled
Heater1
If the heater is “Enabled”, the heater relay will turn on when the water temperature is less
than the desired temperature setting and the filter pump is running. The desired temperature
is in the “Settings Menu”. If applicable, the homeowner will be prompted to enter separate
“pool” and “spa” settings. Depending on the position of the pool/spa suction valve, the
proper temperature setting will be used.
Heater Cooldown
This feature ensures that the heater cools down before water circulation is stopped. When
enabled, the Aqua Logic will continue to run the filter pump for 5 minutes after the heater
turns off. During this period the filter pump LED will flash and also a “Heater Cooldown,
X:XX remaining” message will scroll on the display.
When the filter pump is running and the heater is on: Pressing the “Filter” button once will
cause the heater to turn off, but the filter pump will continue to run for heater cooldown (filter
LED flashing and message on display). Pushing the filter button a second time will override
the heater cooldown operation and turn the filter pump off.
Heater Extend
If “Enabled”, the filter extend logic keeps the filter pump running beyond the normal turn-off
time until the pool (or spa) is heated up to the desired temperature setting (see Settings
Menu). Heater extend will NOT cause the filter pump to turn on, it will only delay the turn
off time when the heater is operating.
+
>
>
+
>
>
+
+
>
>
>
>
+
>
>
Solar Config.
+ to view/change
Solar
Disabled
Solar Extend
Disabled
Solar Priority
Disabled
Push to access solar options
Toggle between Enabled and Disabled (default) Solar
Toggle between Enabled and Disabled (default) Solar Extend
Toggle between Enabled and Disabled (default) Solar Priority
Move to previous/next configuration menu
Move to next menu item or previous/next configuration menu
Move to next menu item
Move to previous/next configuration menu
if “Solar” is enabled
if “Solar” is enabled
Solar
If the solar control logic is “Enabled”, several additional steps must be taken to ensure
proper operation of the solar system. If the solar is operated by a valve, then the Valve3
output must be setup for solar logic. If the solar is operated by a pump, then one of the AUX
relays must be set up for solar logic. Also, the “solar” temperature sensor must be installed.
This sensor is typically mounted near the collector array and is used to sense whether
sufficient solar heat is available.
If solar is “Enabled”, the valve or solar pump relay will turn on when the water temperature is
less than the desired temperature setting AND the solar sensor is hotter than the water. The
19
Solar – the aux relay operates a solar booster pump which will turn on when the filter pump
is running
and solar heat is available and the water is less than the desired temperature
setting. It is important to note that “Solar Control” must be enabled in the “Solar Config.”
menu for proper operation to occur.
Low Speed of a 2-speed Filter Pump – the Aqua Logic will operate the aux relay whenever
the low speed operation of the filter pump is required. It is very important that the “2-speed”
filter pump option be selected under the “Filter Config.” Menu for proper operation.
Super Chlorinate – if “Chlorinator” is enabled, this option allows the user to start a Super
Chlorinate cycle when the Aux button is pressed, rather than using the Settings Menu. Note
that only one button can me assigned to this function.
Aux1 Relay
This feature allows the user to select either “Standard” (default) or “Dimmer” type relay for
the Aux1 output. The optional AQL-DIM dimmer kit must be installed if “Dimmer” is desired.
When “Dimmer” is selected, and the Aux1 output is manually turned on, the “+” and “-”
buttons adjust the level from 20% to 100% (default). The level is saved for the next time the
aux1 output is turned from off to on.
Aux1 Interlock
If “Enabled”, this feature will override the function (Manual On/Off, Countdown Timer,
Timeclock), selected above and turn the aux1 off when: filter pump is off, first 3 minutes of
filter pump operation (allows the pump to prime and get water flowing), when the pool/spa
suction return valves are in any position other than “pool only”, or for the first 3 minutes
after solar turns on (allows air in the solar panels to be purged). Interlock is not available for
solar, low speed filter pump, or dimmer.
Aux1 Freeze Protection
This function protects the pool, plumbing, and equipment against freeze damage. If Freeze
Protection is enabled and the AIR temperature sensor falls below the selected freeze
temperature threshold, the Aqua Logic will turn on the aux relay to circulate the water.
IMPORTANT: this only enables operation of the AUX output during freeze--see the “Filter
Pump Config.” menu to enable freeze protection for the main circulation system. Freeze
Protection is not available for low speed filter pump or dimmer.
Valve3 Config.
+ to view/change
Valve3 Function
Solar
+
+
>
>
>
>
Push to access Valve3 options
Rotates between Timeclock , Solar, In-Floor Cleaner,
and Super Chlorinate
(default)
Move to previous/next configuration menu item
Move to next menu item
Valve3 Interlock
Disabled
Valve3 Freeze
Disabled
+
+
>
>
>
>
Toggle between Enabled and Disabled (default) Valve3 Interlock
Toggle between Enabled and Disabled (default) Valve3 Freeze
Move to next menu item
Move to previous/next configuration menu
for all functions except solar
Valve3 Function
Timeclock (default) – the valve turns on/off at the times set for the Valve3 timeclock in the
Timers Menu (see Operations Manual). The Valve 3 button can also be used to turn the
valve output on or off.
Solar – the valve operates when the filter pump is running and solar heat is available and the
water is less than the desired temperature setting. Solar heating must be enabled in the
“Solar Config. menu for proper operation to occur.
In-Floor Cleaner – the valve switches the water returning to the pool between the in-floor
cleaner and the normal return jets which facilitate efficient surface skimming. The valve will
operate the in-floor cleaner for the first half of each clock hour and then switch to the jets/
skimming for the last half of the hour.