Specifications
15
is selected, then the pool/spa suction and return valve actuators should be connected to the
Aqua Logic. Pressing the POOL/SPA button on the display/keypad will allow the homeowner
to alternate between pool and spa operation.
Spa CountDn
This menu will appear only if Pool/Spa Setup is set to “Pool and Spa”. This setting is the
time, after you manually switch the Pool/Spa valves to “Spa Only”, until the Aqua Logic
automatically returns the valves to their previous positions. It is programmed in increments
of 5 minutes, from “Manual On/Off” (0 minutes) to “21:00” (21 hours). The filter is forced on
during this time period.
Spa Spillover
When spa spillover is “Enabled” and “Pool and Spa”, the homeowner will be able to rotate
through “Pool Only” (both suction and return valves switched to pool), “Spa Only” (both
suction and return valves switched to spa) and “Spillover” (suction valve switched to pool
and return valve switched to spa) by successive presses of the “Pool/Spa) button.
Filter Operation
If “Spa Spillover” is selected, the Aqua Logic will automatically switch the pool/spa suction
and return valves to “spillover” at the start of the programmed pool filtering time period or
when the super-chlorinate function is turned on. The valves will remain in this position for
the remainder of the super-chlorinate period. This option is usually preferable because both
the pool and spa water will be filtered and sanitized.
If “Pool Only” is selected, then the Aqua Logic will switch the pool/spa valves to the “pool
only” position at the start of the programmed pool filtering time period or when the super-
chlorinate function is turned on. This may be desirable on some systems with in-floor
cleaners because it allows the cleaner to operate all the time the pool is being filtered and/or
the super chlorinate is running.
V1=Aux1, V2=Aux2
This menu appears only if the Pool/Spa Setup is “Pool Only” or “Spa Only”. When enabled,
Valve 1 (return) will follow the Aux1 output and Valve 2 (suction) will follow the Aux2 output.
When disabled (default), the return and suction pool/spa valves function normally.
+
>
>
+
>
>
+
+
>
>
>
>
+
>
>
Filter Pump Config.
+ to view/change
Filter Pump
1 Speed
Freeze Protect
Enabled
Freeze Temp
38ºF
Push to access pump options
Toggle between 1-speed (default) and 2-speed options
Toggle between Enabled (default) and Disabled Freeze Protection
Adjust the desired freeze protection temperature (33ºF - 42ºF)
Move to next menu item
Move to previous/next configuration menu
Move to next menu item or previous/next configuration menu
Move to previous/next configuration menu
Filter Pump
Select single speed or 2-speed pump. If a 2-speed pump is configured, one of the AUX
relays must also be configured to control the low speed motor winding on the pump. See
page 3 for specific information regarding the control logic for 2-speed pump operation.
Freeze Protection
Freeze protection is used to protect the pool and plumbed equipment against freeze damage.
If freeze protection is enabled and the AIR temperature sensor falls below the freeze threshold
(see below), the Aqua Logic will turn on the filter pump to circulate the water. If “Pool and
Spa” is selected in the Pool/Spa sub-menu, the valves will also alternate between the pool
and spa every 30 minutes and the filter pump will turn off while the valves are turning. The
chlorinator will not operate if freeze protection is the only reason the pump is running.
Freeze Protection Temperature
Select the temperature to be used for freeze protection. Temperature is adjustable from 33ºF
- 42ºF (1ºC - 6ºC). 38ºF (3ºC) is default. This threshold will be used for all outputs that have
freeze protection enabled.
20
Super Chlorinate – if “Chlorinator” is enabled, this option allows the user to start a Super
Chlorinate cycle when the Valve3 button is pressed, rather than using the Settings Menu.
Note that only one button can me assigned to this function.
Valve3 Interlock
If “Enabled”, this feature will override the function (timeclock or in-floor cleaner) selected
above and turn the valve off whenever the filter pump is off or the pool/spa suction/return
valves are set to “spa only” or “spillover” operation. Interlock is not available with solar.
Valve3 Freeze Protection
This function protects the pool and plumbed equipment against freeze damage. If Freeze
Protection is enabled and the AIR temperature falls below the selected freeze temperature
threshold, the Aqua Logic will turn on the valve to allow circulation of the water. IMPORTANT:
this only enables operation of the Valve3 output during freeze--see the “Filter Pump Config.”
menu to enable freeze protection for the main circulation system.
+
>
>
+
+
>
>
>
>
6B Spa Config.
+ to view/change
6B A, Button 1
Pool/Spa
Select 6B Spa
A
Push to access the 6 Button Spa Side Remote options
Rotates between Pool/Spa, Filter, Lights, Heater1,
Aux1, and Aux2
Rotates between all available remotes
Move to previous/next configuration menu
Move to previous/next menu item or next configuration menu
Move to next menu item
if AQL-SS-6B is connected
Select 6B Spa
This menu only appears if more than one AQL-SS-6B is detected at power up. Select which
of the available remote controls (A, B or C) is to be configured.
6B A, Button 1
This menu allows the user to map each button of the AQL-SS-6B to one of the standard Aqua
Logic functions. The default selections are: Button 1 - Pool/Spa, Button 2 - Filter, Button 3
- Lights, Button 4 - Heater1, Button 5 - Aux1 and Button 6 - Aux2.
+
>
>
Remote Menus
Enabled
Toggle between
Enabled (default) and Disabled Remote Menus
Move to previous/next configuration menu
This feature will prevent unauthorized access to the Settings, Timers, and Configuration
menus from any of the Aqua Logic’s remote display/keypads. When disabled, the remote
display/keypads will only show the default menu and allow on/off control via the pushbuttons.
Note that the function of the Aqua Logic’s built-in display/keypad is unchanged by this
selection. Once disabled, the only way to enable “Remote Menus” is to use the local
display/keypad.
All Timeclocks
7-day
>
>
Move to previous/next configuration menu
+
Toggle between 7-day (default) and Weekend/Weekday time options
This selection affects ALL of the timeclock logic in the Aqua Logic. If “7-day” is selected,
each timeclock will have one set of turn-on/turn-off settings that operate every day of the
week. If “Weekend/Weekdays” option is selected then the user can enter one set of turn-on/
turn-off times for the weekend (fixed as Saturday/Sunday) and another set of turn-on/turn-
off times for weekdays (Monday through Friday).