Operating instructions

FC 100, 200 and 300
Bit (Hex) Unit di-
agnose
bit
PROFIBUS warning word (Par.
9-53)
00000001 160 Connection with DP-master is
not ok
00000002 161 Unused
00000004 162 FDL (Field-bus Data link Layer)
is not ok
00000008 163 Clear data command received
00000010 164 Actual value is not updated
00000020 165 Baudrate search
00000040 166 PROFIBUS ASIC is not transmit-
ting
00000080 167 Initialising of PROFIBUS is not
ok
00000100 152 Drive is tripped
00000200 153 Internal CAN error
00000400 154 Wrong configuration data from
PLC
00000800 155 Wrong ID sent by PLC
00001000 156 Internal error occurred
00002000 157 Not configured
00004000 158 Timeout active
00008000 159 Warning 34 active
FC 100, 200 and 300
Bit (Hex) Comm. option STW (Par. 16-84)
00000001 parameterization ok
00000002 configuration ok
00000004 clearmode active
00000008 baudrate search
00000010 waiting for parameterization
00000020 waiting for configuration
00000040 in data exchange
00000080 not used
00000100 not used
00000200 not used
00000400 not used
00000800 MCL2/1 connected
00001000 MCL2/2 connected
00002000 MCL2/3 connected
00004000 data transport active
00008000 not used
NB!
Par. 16-84
Comm. Option STW
is not part of extended diagnosis.
8.2.6. Warning and Alarm Messages
There is a clear distinction between alarms and warnings. When there is an alarm, the frequency
converter will enter a fault condition. After the cause for the alarm has been cleared, the master
will have to acknowledge the alarm message before the frequency converter can start operating
again. A warning, on the other hand, may come when a warning condition appears, then disappear
when conditions return to normal, without interfering with the process.
Warnings
Warnings within the frequency converter are represented by a single bit within a warning word.
A warning word is always an active parameter. Bit status FALSE [0] means no warning, while bit
status TRUE [1] means warning. Any bit change in the warning word will be notified by a change
of bit 7 in the status word.
8. Troubleshooting VLT
®
Profibus
96
MG.33.C4.02 - VLT
®
is a registered Danfoss trademark