Operating instructions
8) Pour the recommended amount of MPH adder into the fi lter media and add water back to fi lter to expel
any air pockets in the fi lter vessel.
9) Reinstall the control valve back on top of fi lter vessel. You may want to apply some silicone lubricant to the
O-rings, distributor tube and the inside of the fi lter vessel opening to facilitate for easier installation. Allow
the control valve to rest on the fi lter vessel fl ange and with one steady downward motion push the control
into the vessel opening to seat properly. Manually stage control valve to the service position. Refer to
Section 5, “HOW TO MANUALLY INITIATE IMMEDIATE REGENERATION”.
10) Reinstall the clamp assembly around both the control valve and fi lter vessel fl ange and secure the latch.
See Figure 7 for proper orientation in Section 3.
11) Connect both the bypass and the drain line to the control valve and hand tighten only the connection nuts.
12) Slowly open the inlet side of the bypass and pressurize the fi lter, check for leaks, correct if necessary.
13) Slowly open the outlet side of the bypass and pressurize the dwelling.
14) Manual stage the control to backwash and clean the fi lter media of any fi nes that would be present till clear.
Allow the control to complete regeneration cycle completely and return to service. Refer to Section 5,
“HOW TO MANUALLY INITIATE IMMEDIATE REGENERATION”.