® VERSAFILLER Model PWSBF Installation Instructions The VersaFiller is an extension of the Aqua Pointe product line that mounts directly above Versacooler I and II products. No additional electrical connections are required. If installed onto a refrigerated cooler, then chilled water can be dispensed through the Versa Filler. Otherwise, room temperature water will be dispensed. The VersaFiller is shipped partially assembled.
Section 1: Getting Started What’s Included: (Top cap) VersaFiller Sports Bottle Filler- (with wrapper, alcove and top cap installed onto the frame) Drip tray Gasket Anti splash grate Anti Splash grate screws (2) Quick connect tee fitting 38” of ¼ OD plastic tubing with 19” of sponge tubing insulation Installation instructions Tools required: 3/8 drill bit that will drill through SS top Electric drill Small tubing cutter for copper tube 1/4 “ nut driver # 2 Phillips screw driver
Section 2: Rough In Drawing Oasis PWSBF: Versacooler® II Models PAC, P8AC with VersaFiller
Section 2: Rough In Drawing Oasis PWSBF: Versacooler® II Split Level Models with VersaFiller * On split level models, the VersaFiller must be mounted on the low unit in order to meet ADA guidelines.
Section 3: Installation A: Drilling hole in the top for water line connection. 1. Disconnect power by UNPLUGGING unit. It might be necessary to remove the front panel to get access to the power. 2. Turn OFF water supply to the unit. It might be necessary to remove the front panel to access the water stop valve. 3. Place hole template onto cooler top so it is aligned with the left side of unit and wall. SEE NEXT PAGE FOR TEMPLATE 4. Mark hole location 5. Remove top from unit. Mark hole location.
ALIGN THIS EDGE WITH LEFT EDGE OF COOLER TOP Mark this center point on the top. Remove the top from the cooler. Then drill a 3/8 hole through the top at the marked center point.
Section 3: Installation B: Connecting the water line If the cooling tank is non-pressurized, then go to the “Pressurizing the cooling tank” addendum section. Otherwise, proceed to step 1 below. Non-pressurized units are single units made since December of 2009. Refer to the schematic below to identify the system that you have. Water valve/ regulator NONPRESSURIZED COOLING TANK 1.
Section 3: Installation: For the P8AC Version: Versacooler II 2. Disconnect tubing from the elbow on the valve. 3. Using the 30” piece of tubing provided, cut 6” and install it on the end of the TEE. Install the remaining tubing onto the branch of the TEE. Connect the other end of the TEE to the tank outlet tubing (tube that was disconnected from the elbow). TEE 4. 24” tubing 6” tubing Route the TEE and tubing under the waste drain and connect the 6” length to the water valve elbow.
Section 3: Installation: For the P8AM Version: Versacooler I Remove tar tape 2. Remove tar tape from the insulation on the outlet tube. 3. 4. Pull back insulation and cut the copper tube with a tubing cutter. Cut where there is at least 1 inch of straight tubing on each side of the cut. Install TEE fitting by connecting the copper tubing to each end. Then install the 30” piece of plastic tubing to the TEE branch.
Section 3: Installation: Final steps for both product families: 5. Feed tubing up through the top and attach the top to the cooler. TIP: For the P8AM, it is easier to connect the outlet tube to the bubbler if the front nose is removed. C: Mounting the frame to the wall 1. Place rubber gasket on top of the cooler so it is centered left/right and against the wall.
Section 3: Installation 2. Set the wall frame onto the gasket. Center it left/right and push it against the wall and mark hole locations for wall fasteners. The gasket will set the frame at the proper height. Use mounting slots that will provide the proper securing location. Make sure to pull the plastic tubing up through the hole in the frame. 3. Secure frame to the wall with fasteners (not provided). Pull plastic tubing up through the hole in the frame. 4. Slide sponge tubing insulation over water line.
Section 3: Installation 5. Set the VersaFiller cabinet into place. MAKE SURE the cabinet fits into the groove in the rubber gasket on both sides and front of the wrapper. VersaFiller cabinet Groove in the gasket 6. Attach VersaFiller assembly and top cap to the frame using the six (6) torx screws.
Section 3: Installation 7. Install the drip tray and anti-splash grate into the alcove area and secure with the two (2) stainless steel phillips head screws. Anti-splash grate screws (provided) Anti-splash grate Drip tray 8. Turn ON water supply and check for leaks. Press the activation button and release any trapped air from the system. Plug in the power cord and replace the front panel IF it was removed earlier.
Addendum Section: Pressurizing Cooling Tank The water should already be turned OFF and the power disconnected. Unit as it appears with top removed STEP 1 Unplug un-insulated water line from water valve inlet (JG elbow located left side of water valve facing the front of the cooler). Set tubing aside (careful to not contaminate water contact end). STEP 2 Unplug tubing from JG elbow leading to cooling tank inlet.
STEP 3 Plug un-insulated tubing that was removed in step 1 into JG elbow leading to the cooling tank from step 2. STEP 4 Unplug tubing that is connected to the water valve outlet (JG elbow located on the right side of valve facing the cooler). STEP 5 Connect tubing from step 4 to JG elbow on the left side of the valve.
Step 6 Unplug JG tubing from the cooling tank outlet. Do not set it down. Step 7 Using tubing removed in step 6, plug into JG elbow on the right side of the valve. (be sure to rout the tubing under existing tubing installed in step 4 as shown) Step 8 Using tubing that is connected to the JG elbow left side of valve (done in step 4), and plug the other end to the JG fitting at the top of the cooling tank.
25 33 26 12 13 3 28 14 17 2 15 27 29 16 18 19 24 1 32 20 9 22 8 30 21 23 4 6 22 25 22 11 EXPLODED PARTS BREAKDOWN 10 5 Accessory: Vandal resistant screw kit: P/N 036704-001, includes torx bits and replacement screws for items 4 and 25.