user manual
ºC ºF
Ti
Calcuim
Hardness
Ci
Tot al
Alkalinity
Ai
53
60
66
76
84
94
103
12
16
19
24
29
34
39
.3
.4
.5
.6
.7
.8
.9
How to use:
Measure pool pH, temperature, calcium hardness,
and total alkalinity. Use the chart above to determine Ti, Ci,and
Ai from your measurements. Insert values of pH, Ti, Ci and Ai
into the above equation. If Si equals .2 or more, scaling and
staining may occur. If Si equals -.2 or less corrosion or irritation
may occur.
Si = pH + Ti + Ci + Ai - 12.
1
-.2
0.2
CORROSIVE SCALING
75 75
100 100
125 125
150 150
200 200
250 250
300 300
400 400
600 600
800 800
1.5 1.9
1.6 2.0
1.7 2.1
1.8 2.2
1.9 2.3
2.0 2.4
2.1 2.5
2.2 2.6
2.4 2.8
2.5 2.9
OK
3
1. Preparing Pool/Spa Water
General Water Chemistry
Salt is required only if you are using the chlorinator features on the Aqua Logic Control. If you are NOT
using the chlorinator, it is recommended that you follow all of the other chemistry recommendations be-
sides salt. Refer to the description of the Aqua Logic configuration menu for information on enabling/
disabling the chlorinator (see page 23).
Water Chemistry
The table below summarizes the levels that are recommended by the Association of Pool and Spa Profes-
sionals (APSP). The only special requirements for the Aqua Logic are the salt level and stabilizer.
Saturation index
The saturation index (Si) relates to the calcium and alkalinity in the water and is an indicator of the pool
water “balance”. Your water is properly balanced if the Si is 0 ±0.2. If the Si is below -0.2, the water is
corrosive and plaster pool walls will be dissolved into the water. If the Si is above +0.2, scaling and
staining will occur. Use the chart below to determine the saturation index.
36
6B Spa Config.
+ to view/change
6B A, Button 1
Pool/Spa
Select 6B Spa
A
Push to access the 6 Button Spa Side Remote options
Rotates between System Off, Pool/Spa, Filter, Lights, Heater1, Valve3,
Valve4, and all available Aux outputs
Rotates between all available remotes
Move to previous/next configuration menu
Move to previous/next menu item or next configuration menu
Move to next menu item
+
+
+
>
>
>
>
>
>
if AQL-SS-6B is connected
Select 6B Spa
This menu only appears if more than one AQL-SS-6B is detected at power up. Select which
of the available remote controls (A, B or C) is to be configured.
6B A, Button 1
This menu allows the user to map each button of the AQL-SS-6B to one of the standard Aqua
Logic functions. The default selections are: Button 1 - Pool/Spa, Button 2 - Filter, Button 3
- Lights, Button 4 - Heater1, Button 5 - Aux1 and Button 6 - Aux2.
Digital Spa Config.
+ to view/change
Digital A, Button 1
Pool/Spa
Digital A, Setpoint
Heater1
Select Digital Spa
A
Push to access the Digital Spa Side Remote options
Rotates between System Off, Pool/Spa, Filter, Lights, Heater1, Valve3,
Valve4, and all available Aux outputs
Rotates between heaters that are enabled
Rotates between all available remotes
Move to previous/next configuration menu
Move to previous/next menu item
Move to previous menu item or next configuration menu
Move to next menu item
+
+
+
+
>
>
>
>
>
>
>
>
if AQL-SS-D is connected
Select Digital Spa
This menu only appears if more than one AQL-SS-D is detected at power up. Select which of
the available remote controls (A, B or C) is to be configured.
Digital A, Button 1
This menu allows the user to map each button of the AQL-SS-D to one of the standard Aqua
Logic functions. The default selections are: Button 1 - Pool/Spa, Button 2 - Filter, Button 3
- Lights, Button 4 - Heater1, Button 5 - Valve3, Button 6 - Valve4, Button 7 - Aux1 and Button
8 - Aux2.
Digital A, Setpoint
If more than one heater is installed, select the spa heater you wish to control. If no heaters
are installed, “Heaters Disabled” will be displayed.
Remote Menus
Enabled
Toggle between Enabled (default) and Disabled Remote Menus
Move to previous/next configuration menu
+
>
>
This feature will prevent unauthorized access to the Settings, Timers, and Configuration
menus from any of the Aqua Logic’s remote display/keypads. When disabled, the remote
display/keypads will only show the default menu and allow on/off control via the pushbuttons.
Note that the function of the Aqua Logic’s built-in display/keypad is unchanged by this
selection. Once disabled, the only way to enable “Remote Menus” is to use the local
display/keypad.