user manual
Optional Base Station
The optional base station, Goldline part number AQL-BASE-RF or AQL2-BASE-RF, must be installed
if any wireless remote control is used. Use the proper base station for the desired remote control - AQL-
BASE-RF for AQL remote controls or AQL2-BASE-RF for AQL2 remote controls. To install the base
station, remove the knockout on the upper left side of the Aqua Logic main control unit, insert the base
station, and then tighten the nut from the inside. Also refer to the Base Station manual and the diagram on
page 20.
Optional Valve Actuators
For optional actuators supplied with the Aqua Logic—note that the internal cams in the actuator may also
have to be adjusted depending on the way the actuator is mounted on the valve and the desired valve
action.
8
RETURN
SUCTION
OUT
(Common)
IN
(Common)
OUT
IN
OUT
IN
31
Lights Group
The Lights Group function allows the user to perform multiple tasks with a single push of the
“Lights” button. When setting up a Group function, refer to page 22 for specific programming
information. There are two Group menus; the first menu determines how the group command
will be initiated (Manual On/Off, Countdown Timer, or Timeclock) and the second menu
selects the desired functions and their respective control parameters.
When activating Group functions, be aware that the most recent Group function that is
initiated will override any previous Group function.
Lights Freeze Protection
This function helps protect equipment that is wired to the lights relay against freeze damage.
If Freeze Protection is enabled and the AIR temperature sensor falls below the selected freeze
temperature threshold, the Aqua Logic will energize the lights relay. IMPORTANT: this only
enables operation of the lights relay during freeze--see the “Filter Pump Config.” menu to
enable freeze protection for the main circulation system. Freeze Protection is not available for
low speed filter pump, dimmer, or group functions.
Spa Filter Config.
+ to view/change
Spa Filter Pump
1 Speed
Freeze Protect
Enabled
Push to access Spa Filter options
Toggle between 1 speed (default) and 2 speed options
Move to previous/next configuration menu item
Move to next menu item
Toggle between Enabled (default) and Disabled Freeze Protection
Move to previous/next configuration menu
+
>
>
+
>
>
+
>
>
if “Pool & Spa Dual” is selected
Spa Filter Pump
For 2-speed pumps: When a 2-speed pump is configured, one of the AUX relays must also
be configured to control the low speed motor winding on the pump (see page 15 for wiring
and page 31 for AUX configuration). See the Operation manual for specific information
regarding the control logic for 2-speed pump operation.
Freeze Protection
Freeze protection is used to protect the spa and plumbed equipment against freeze damage.
If freeze protection is enabled and the AIR temperature sensor falls below the freeze thresh-
old (selectable in Filter Pump Configuration Menu - page 25), the Aqua Logic will turn on the
spa filter pump to circulate the water.