user manual
Base Station
Plug in the pigtail connector from the wireless base station into the “wireless” connector on the main PCB
in the Aqua Logic control unit.
PS-16 Expansion Unit
Use four conductor cable (typically phone cable) to connect the PS-16 Expansion Unit to the Aqua Logic
Control Center as shown below. Note that the terminals on both the Aqua Logic main unit and the PS-16
Expansion Unit are numbered: Connect 1 to 1, 2 to 2, etc. Refer to diagram below.
Flow Switch
Only applicable if the chlorinator function is enabled and/or the flow monitor feature is desired.
The flow switch cable plugs into the Aqua Logic Control Center at the position shown in the diagram on
page 13. Ensure that the connector catch “snaps” in order to provide a reliable connection.
Turbo Cell
Only applicable if the chlorinator function is enabled. The Turbo Cell should be plugged in after the
Aqua Logic cover panel is put back in place. Refer to page 13 for the location of the connector.
20
Temperature Sensors
The Aqua Logic utilizes 10K ohm thermistor type sensors. Three sensors (water temperature, air tem-
perature and solar temperature (spa temperature for “Pool and Spa-Dual”)) are included. If the Aqua
Logic is being used to control a solar heating system, the solar sensor is required. The sensors are
provided with a 15 ft. cable. If a longer cable is required, contact the Goldline service dept. (888-921-
7665) for information on suitable cable types and splices. See Temperature Sensors on page 6 for
directions on installing the sensors.
Wired Remote Display/Keypad
The Aqua Logic main unit can connect to a maximum of 3 remote wired display/keypads. One remote
wired display/keypad is included with the Aqua Logic, additional wired display/keypads must be ordered
separately.
Use four conductor cable (typically phone cable) to connect the wired remote display/keypad with the
Aqua Logic Control Center as shown below. The maximum wiring distance is 500ft. (160m). Note that
the terminals on both the Aqua Logic main unit and the wired remote display/keypad are numbered:
Connect 1 to 1, 2 to 2, etc. Refer to diagram below.
If multiple remote display/keypads are installed: Never connect more than 2 wires to any terminal
block. Two remotes can be wired back to the Aqua Logic main unit or the second display/keypad (and
third, if applicable) can be “daisy chained” with one display/keypad wired to the next. The maximum wire
run from the Aqua Logic main unit to the furthest remote display/keypad is 500 ft (160m).
19
Base Station
AQL-BASE-RF
or
AQL2-BASE-RF
Tighten nut
Main PCB
Connector for
Base Station
Aqua Logic Control Center
1
1
2
2
3
3
4
4
PS-16 Expansion Unit
Connect screw terminals
“1” to “1”, “2” to “2”, etc.
Wired Remote
Display unit
500 ft max
1
2
3
4
Connect screw terminals
“1” to “1”, “2” to “2”, etc.
12
34
AIR
SENSOR
SOLAR/SPA
SENSOR
POOL/SPA
SENSOR
A
ir
Solar
Pool/Spa
Heater1
Heater2