user manual
General Purpose Outlet
If desired, a duplex receptacle with weatherproof cover (supplied by installer) may be installed in the
knockouts on the lower right side of the Aqua Logic enclosure. Per code, the receptacle should be a
GFCI type. Alternatively, connect a standard receptacle to a GFCB.
Aqua Logic Control Power
The Aqua Logic requires 120VAC, 2A power to operate the control logic circuits and the chlorinator.
This power should be connected to one of the circuit breakers.
!
WARNING: 120VAC only (permanent damage if connected to 240V)
High Voltage (120/240V) Pool Equipment
All Aqua Logic relays are double pole (they make/break both “legs” of 240V circuits) and are rated at
3HP/30A at 240V (1½HP/30A at 120V). Refer to the diagram below for typical relay wiring.
!
WARNING: Do not use the Aqua Logic to control an automatic pool cover. Swim-
mers may become entrapped underneath the cover.
14
240 VAC
Load
120 VAC
Load
Wiring relays for 240 VAC
Pool Equipment
Wiring relays for 120 VAC
Pool Equipment
120 VAC
Load
Wiring GFCB for 120 VAC
Pool Equipment
Factory
Prewired
Field
Wired
120, 2VA
Pool/Spa Config.
+ to view/change
Pool/Spa Setup
Pool and Spa-Std
Spa Spillover
Enabled
Heaters
Htr1=Spa,Htr2=Pool
Filter Operation
Spa Spillover
Push to access Pool/Spa options
Rotates between Pool and Spa-Std , Pool and Spa-Dual,
Pool Only, and Spa Only options
(default)
Toggle between Enabled and Disabled Spa Spillover(default)
Toggle between Htr1=Spa, Htr2=Pool (default) and Shared Heaters
Toggle between Pool Only and Spa Spillover options(default)
Move to previous/next configuration menu
Move to next menu item
Move to next menu item or previous/next configuration menu
Move to next menu item
Move to previous/next configuration menu
if “Pool and Spa-Std or Dual” is
selected and if “Spa Spillover” is enabled
+
+
>
>
>
>
+
+
+
>
>
>
>
>
Spa - CountDn
00:30
Adjust time setting (Manual On/Off, 0:05, 0:10, 0:15..., (default is 4:00))
Move to next menu item
if “Pool and Spa-Std” is selected
if “Pool and Spa-Dual” is selected
if “Pool and Spa-Std or Dual” is selected
+
>
>
>
V1=Aux1, V2=Aux2
Disabled
Toggle between Enabled and Disabled
(default)
if “Pool Only” or “Spa Only” is selected
+
+
Move to previous/next configuration menu
>
>
>
>
Filter Off Valve
Change: Enabled
Toggle between Enabled and Disabled (default)
if “Pool and Spa-Std” is selected
Move to previous/next configuration menu
Pool/Spa Setup
If “Pool Only” or “Spa Only” are selected, then the pool/spa valves are not needed and
pushing the POOL/SPA button on the display/keypad will have no effect. If “Pool and Spa-
Std” is selected, then the pool/spa suction and return valve actuators should be connected
to the Aqua Logic. Pressing the POOL/SPA button on the display/keypad will allow the
homeowner to alternate between pool and spa operation. If “Pool and Spa-Dual” is selected,
then only the Pool/Spa return valve actuator should be connected to the Aqua Logic.
For more information on “Pool and Spa-Std” and “Pool and Spa-Dual”, refer to Section 3,
Plumbing, on pages 9-12.
Heaters
This menu will only appear if Pool/Spa setup is set to “Pool and Spa-Dual”. This allows the
heater(s) to either be shared between the pool and spa (“Shared” selected) or for Heater1 to
be dedicated to the spa and Heater2 to be dedicated to the pool (“Htr1=Spa, Htr2=Pool”
selected).
Spa CountDn
This menu will appear only if Pool/Spa Setup is set to “Pool and Spa-Std”. This setting is the
time, after you manually switch the Pool/Spa valves to “Spa Only”, until the Aqua Logic
automatically returns the valves to their previous positions. It is programmed in increments
of 5 minutes, from “Manual On/Off” (0 minutes) to “21:00” (21 hours). The filter is forced
on during this time period.
Spa Spillover
When spa spillover is “Enabled” and “Pool and Spa-Std”, the homeowner will be able to
rotate through “Pool Only” (both suction and return valves switched to pool), “Spa Only”
(both suction and return valves switched to spa) and “Spillover” (suction valve switched to
pool and return valve switched to spa) by successive presses of the “Pool/Spa” button. For
“Pool and Spa-Dual”, only “Pool Only” and “Spillover” are available.
25