User's Manual

-9-
2) Powering by Batteries
V-Mount Battery Anton Bauer Battery
* Batteries: Voltage 12~16.8V; Recommended ≥15A continuous discharge.
* The LS 300x can be operated using a single battery for up to half of the
xture's maximum output. Plugging the light into AC
power
or using two batteries allows you to utilize the light's full output. When powering the light from a single battery, you mus
t install the
battery on the right side of the of the control box, or the light will not turn on.
* Do not use non-14.4v batteries (batteries with voltages outside of the 12-16.8V range). Using higher voltage batteries will
damage the power supply and the lighting xture.
* Only use batteries that support the necessary continuous current discharge speci
cations mentioned above. If non-compatible
batteries are used, the batteries will enter a protection state and the lighting xture will not operate as intended.
* Customers can choose V-Mount or A-Mount battery plates for their control boxes upon purchase according to their needs.
1) Powering by AC
7. Powering up the controller
Neutrik® powerCON
Male Connector
Neutrik® powerCON Female
Locking Connector
1
2
AC 100V-240V
~
~
PUSH
To disconnect the Neutrik® powerCon cable, pull back on the yellow release tab on the
cable connector, and rotate the connector counterclockwise.
ai15858101745_LS_300x Product_Manual_EN.pdf 10 2020/4/2 下午2:49