Product Manual

6
Aptos Microinverter: 2-in-1 Unit and Single Unit
DTU: MAC
TM
DTU:
Meter: Chint Meter (DDSU666)/Chint Meter (DTSU666)/CCS WattNode
Meter
b. Export Control Type.
Type 1: Zero Export: to limit the exporting power to zero so that it can prevent the
generated power feed back to the grid.
Type 2: Export Limit: to limit the exporting power within a certain value.
Type 3: Production and Consumption Monitoring: enable to measure the PV
generating under a high accuracy.
c. Installation Diagram.
MAC 800R
MAC 800R
MAC 800R
MAC 800R
Note: Please refer to Aptos Export Management Technical Note” for more details.
3.3 Remote Active Power Control (RS485 port)
Some countries require generating plants to be equipped with a logic interface (input port) in
order to cease output active power or limit active power to a regulating level. This logic
input can be RS485 port, Ethernet port, etc. MAC
TM
DTU provide RTU Modbus protocol
over RS485 port for this remote active power control. For more information, please refer to
“Modbus implementation Technical Note”.
3.4 DRM Port
DRM port is provided to support several demand response modes as below by connecting
© 2021 Aptos Solar Technology, LLC. All rights reserved.
MAC
TM
DTU