8.1 YC600 Microinverter Datasheet
Anti-Islanding Protection
Yes
Over Current Protection
Yes
Reverse DC Polarity Protection
Yes
Overload Protection
Yes
Warranty
10 Years Standard ; 25 Years Optional
Certificate&Compliance
Safety And EMC Compliance
UL1741;CSA C22.2 No. 107.1-16;CA Rule 21 (UL 1741 SA); FCC Part15; ANSI
C63.4;ICES-003
Grid Connection Complianc
IEEE1547
NEC Compliance
NEC2014 & NEC2017 Section 690.11 DC Arc-Fault circuit Protection
NEC2014 & NEC2017 Section 690.12 Rapid Shutdown of PV systems on
Buildings
*APsystems online Energy Management Analysis (EMA) platform
Note 1: Utility Interconnection Voltage and Frequency Trip Limits and Trip Times
Voltage and frequency limits for utility Interaction
Simulated utility source
Maximum time (sec)
(cycles) at 60 Hza
before cessation of
current to the
simulated utility
Trip time accuracy
Voltage (V)
Frequency (Hz)
< 0.50 Vnor
Rated
160ms
+/-80ms
0.50 Vnor V < 0.88 Vnor
Rated
1000ms
+/-200ms
1.10 Vnor < V < 1.20 Vnor
Rated
1000ms
+/-200ms
1.20 Vnor V
Rated
160ms
+/-80ms
Rated
f > 60.5
160ms
+/-200ms
Rated
f < 59.3
160ms
+/-200ms