User and installation manual
APsystems YC600 Installation/User Manual
20
8.1 YC600 Microinverter Datasheet
Region
USA
Model
YC600-NA
Input Data (DC)
Recommended PV Module Power (STC) Range
250Wp-440Wp+
MPPT Voltage Range
22V-48V
Operation Voltage Range
16V-55V
Maximum Input Voltage
60V
Maximum Input Current
12A x 2
Maximum Input Short Circuit Current
13.2A
Output Data (AC)
Maximum Continous Output Power
548VA
Peak Output Power
600VA
Nominal Output Voltage/Range
240V/211V-264V
Adjustable Output Voltage Range
160-278V
Nominal Output Current
2.28A
Maximum Units Per Branch
7 (14PV modules) per 20A AC breaker
Nominal Output Frequency/Range
60Hz/59.3Hz-60.5Hz
Adjustable Output Frequency Range
55-65Hz
Power Factor(Adjustable)
0.8leading…0.8lagging
Total Harmonic Distortion
<3%
Maximum Output Overcurrent Protection
6.3A
Efficiency
Peak Efficiency
96.7%
CEC Efficiency
96.5%
Nominal MPPT Efficiency
99.5%
Night Power Consumption
20mW
Mechanical Data
Operating Ambient Temperature Range
-40
o
F to +149
o
F (-40 °C to +65 °C )
Storage Temperature Range
-40
o
F to +185
o
F (-40 °C to +85 °C )
Dimensions (W x H x D)
10.3” × 7.4” × 1.3” (260mm X 188mm X 31.5mm)
Weight
5.7lbs(2.6kg)
AC Bus Maximum Current
25A(12AWG)
Connector Type
MC4 Type
Enclosure Environmental Rating
Type 6
Cooling
Natural Convection - No Fans
Overvoltage Category
OVC II For PV Input Circuit, OVC III For Mains Circuit
Utility Interconnection Voltage And Frequency Trip Limits
And Trip Times
See NOTE 1 Below
Trip Limit And Trip Time
Accuracy
Voltage
+/-2V
Frequency
+/-0.1Hz
Alternate Trip times
See NOTE 1 Below
Features
Communication (Inverter To ECU)
Wireless
Transformer Design
High Frequency Transformers, Galvanically Isolated
Monitoring
Via EMA* Online Portal
Over/Under Voltage Protection
Yes
Over/Under Frequency Protection
Yes