Product Manual
Table Of Contents
- 1.Important Safety Instructions
- 2.APsystems Microinverter System Introduction
- 2.APsystems Microinverter System Introduction
- 3.APsystems Microinverter QS1 Introduction
- 4.APsystems Microinverter System Installation
- 4.1 Additional Installation components from APsyst
- 4.2 Required Parts and Tools from you
- 4.3 Installation Procedures
- 4.3.1 Step 1 - Verify the grid voltage to match wi
- 4.3.2 Step 2 - The AC bus distribution
- 4.3.3 Step 3 - Attach the APsystems Microinverters
- 4.3.4 Step 4 - Ground the system.
- 4.3.5 Stpe 5 - Connect the APsystems microinverter
- 4.3.6 Step 6 - Install a AC bus protective end cap
- 4.3.7 Step 7 - Connect APsystems Microinverters t
- 4.3.8 Step 8 - Complete the APsystems installation
- 5.APsystems microinverter system operating instru
- 6.Troubleshooting
- 7.Replace a microinverter
- 8.Technical Data
- 9.Wiring Diagram
- 10.QS1
QS1 Installation/User Manual
16
7.Replace a microinverter
Follow the procedure to replace a failed APsystems Microinverter
A. Disconnect the APsystems Microinverter from the PV Module, in the order shown below:
1. Disconnect the inverter AC connector from the AC Bus.
2. Disconnect the first AC connector in the branch circuit.
3. Disconnect the PV module DC wire connectors from the microinverter.
4. Remove the Microinverter from the PV array racking.
B. Install a replacement Microinverter to the rack. Remember to observe the flashing LED
light as soon as the new Microinverter is plugged into the DC cables.
C. Connect the AC cable of the replacement Microinverter o the AC bus.
D. Close the branch circuit breaker, and verify operation of the replacement Microinverter.