Product Manual
Table Of Contents
- 1.Important Safety Instructions
- 2.APsystems Microinverter System Introduction
- 2.APsystems Microinverter System Introduction
- 3.APsystems Microinverter QS1 Introduction
- 4.APsystems Microinverter System Installation
- 4.1 Additional Installation components from APsyst
- 4.2 Required Parts and Tools from you
- 4.3 Installation Procedures
- 4.3.1 Step 1 - Verify the grid voltage to match wi
- 4.3.2 Step 2 - The AC bus distribution
- 4.3.3 Step 3 - Attach the APsystems Microinverters
- 4.3.4 Step 4 - Ground the system.
- 4.3.5 Stpe 5 - Connect the APsystems microinverter
- 4.3.6 Step 6 - Install a AC bus protective end cap
- 4.3.7 Step 7 - Connect APsystems Microinverters t
- 4.3.8 Step 8 - Complete the APsystems installation
- 5.APsystems microinverter system operating instru
- 6.Troubleshooting
- 7.Replace a microinverter
- 8.Technical Data
- 9.Wiring Diagram
- 10.QS1
QS1 Installation/User Manual
10
4.APsystems Microinverter System Installation
4.3.5 Stpe 5 - Connect the APsystems microinverter to AC bus cable
Push the microinverter AC connector to the trunk cable connector. Listen for the "Click".
Figure 3
Best Practice: Use the Bus Cable Unlock Tool of AC Bus to split the connectors.
Figure 4
AC connector interface as follows. Cover any unused connectors with Bus Cable Y-CONN Cap
to protect the connectors.
Figure 5 Figure 6
4.3.6 Step 6 - Install a AC bus protective end cap at the end of AC bus
cable
a. Strip cable jacket. c. Insert the wires into the cable clamps.
b. Insert the cable end into the seal. d. Rotate the nut with 3.3N·m until the
latching mechanism meets the base.
Figure 7
Click
Nut
Seal
Body