Install Instructions

TABLE 3 – CYCLE TIME SETTING (MINUTES) FOR AIRFLOW DELIVERED VS. AIRFLOW REQUIRED FOR 1 HOUR CYCLE
CFM Delivered
CFM Required
20 30 40 50 60 70 80 90 100
60 20 30 40 50 60 70 80 90 100
80 15 25 30 40 45 55 60 70 75
100 15 20 25 30 35 40 50 55 60
120 10 15 20 25 30 35 40 45 50
140 10 15 15 20 25 30 35 40 45
160 10 10 15 20 25 25 30 35 40
INSTALLER SETTINGS
90-1854
With the dehumidifier power
switch on, press the ON/OFF
button to turn the dehumidifier
off
90-1854
Press and hold the MODE button
for 3 seconds to access the
installer settings menu� Press
and release the MODE button
repeatedly until the VENT
DISABLED screen appears�
90-1854
Press the or button to
ENABLE ventilation, then press
the MODE button to set Timed or
Auto ventilation�
90-1854
Press the or button to
toggle between VENT TIMED,
VENT AUTO-B, VENT AUTO-C and
VENT AUTO-D (refer to page 20
for a description of each)� Press
the MODE button to select the
desired ventilation method and
adjust the ventilation time�
90-1854
Press the or button
to set the desired amount of
ventilation time per hour from
0to60 minutes�
90-1854
To complete, press the MODE
button repeatedly until DONE
appears on the display
22 English