SETTING THE DESIRED HUMIDITY LEVEL
1. Plug in dehumidifier and turn on/off switch ON� See FIGURE 5
2. Press the ON/OFF button to turn the dehumidifier control ON� The display will show the
current setting, and the dehumidifier blower will turn on to start sampling the air
3. The and buttons allow the humidity level to be set from 40% to 80% relative
humidity� Use the ON/OFF button to turn the dehumidifier ON or OFF
Set the control at 55%RH when first installed� Allow the dehumidifier to run until it reaches
the setting before deciding if you want to change the setting� See FIGURE 6
If you prefer the air to be more dry, decrease the humidity setting�
If you prefer the air to be less dry, increase the humidity setting�
4. After three (3) minutes of sampling, the measured humidity will be compared to the setting:
a. If the humidity is above the setting, the dehumidifier compressor turns on and “AIR
SAMPLING” will be replaced by “DEHUMIDIFYING”� The compressor remains on until the
measured humidity falls 3% RH below the setting� See FIGURE 7
b. If the measured humidity is below the setting, the blowers turn off and the display
returns to showing the RH setting�
5. The dehumidifier will sample again every 60 minutes, or at any time if the humidity setting
is lowered�
Your comfort is the best measure of how to adjust your setting� When first installed, your
dehumidifier has to remove all the moisture that is initially in your home� The home acts like
a sponge so the moisture in the materials of your home is at the same level as the air� After
drying the air, the materials of the home will release moisture back into the air until they are
again at the same level� As a result, it is not uncommon for the dehumidifier to operate for an
extended period when first installed�
Your dehumidifier is equipped with two features that protect against unwanted energy
consumption� Defrost is a normal operating mode that helps to prevent significant ice formation
on the refrigeration system coil� The dehumidifier display will show “DEFROSTING” when
operating in this mode� This mode can occur when there is not enough air moving through the
dehumidifier or if the temperature and/or humidity of the incoming air is too low� The second
protection feature is the E8 code� E8 on the dehumidifier display indicates that the air entering
the dehumidifier is below 50°F or above 104°F, or the dew point of the incoming air is below
40°F� There would be a significant reduction in dehumidifier efficiency if the dehumidifier
operated outside of these conditions� Low dew point conditions can be seen in some basements
or crawl spaces and usually occur in the Winter and Spring months� The dehumidifier continues
to monitor the incoming air and when the conditions are within the operating range, E8 will be
removed from the display and dehumidification will begin as needed�
ENERGY SAVINGS TIPS
Energy Savings Tip #1: Adjust the humidity setting to be as high as is comfortable to
reduce dehumidifier run time� If it feels clammy or “smells musty”, lower the humidity
setting� To save energy, turn the dehumidifier to OFF when you open your windows, just as
you would with air conditioning�
Energy Savings Tip #2: If vacating your home for an extended period in the summer, set
the RH at 55% and set your thermostat as high as you are comfortable setting it to in the
cooling mode� Consult with appropriate professionals regarding the highest temperature
that is safe for your pets or possessions� This will keep the humidity at a controlled level
while minimizing the amount of cooling energy used�
ON/OFF
SWITCH
90-1908
90-1853
90-1853
FIGURE 5 – ON/OFF SWITCH
FIGURE 6
FIGURE 7
6 English