Installation Guide

7 English
REPOSITIONING THE CONTROL FOR THE
APPLICATION
Locate the onboard control panel on the top of the
dehumidifier or at the front of the dehumidifier if the
control panel cannot be seen/accessed in the top
orientation. It may also be rotated 180 degrees in either
orientation
(see Figure 10)
.
2
1
2
1
3
90-1884
Figure 9: Control Panel Location
1 - Control Panel Door
2 - Control Panel
3 - Filter Access Door
90-2525
Figure 10: Control Panel Rotated 180 Degrees
MOVING THE CONTROL
1. Remove the front control panel door.
2. Remove the filter access door and filter.
3. Detach the onboard control panel by removing the
four (4) screws around the control panel.
OTE: N Use one hand to support the bottom of the
onboard control panel when removing.
4. Keep the control panel in the unit and relocate to
the front access hole.
5. Secure the control panel with the same four screws
used to attach the control panel to the top of the
unit.
6. Secure the control panel door to the top of the unit.
INSTALLING THE DUCT COLLARS
Use the screws in the parts bag to attach the duct
collars to the inlet and outlet of the dehumidifier.
The outlet collar has a backflow damper.
The outlet duct collar may be attached to the top or
end of the unit. Move the outlet cover to the location
not being used.
See Figure 11
.
Make sure there are no bends in the ductwork
coming off the outlet for a minimum of 4". This
precaution will ensure that the ductwork will not
interfere with the backflow damper function.
1
1
2
3
5
4
6
90-2592
Figure 11: Fully Ducted Installations
1 - Inlet Duct Collar
2 - Outlet Cover
3 - Outlet Duct Collar w/
Back Draft Damper
4 - End Discharge
5 - Move Outlet Cover
and Install Outlet
Duct Collar to Top
Discharge Location
6 - Top Discharge