Installation Guide
6 English
SPECIFICATIONS
Model E080 Model E100
Unit Weight 63 lbs. 64 lbs.
Capacity
80°F, 60% RH Conditions
80 pints per day @ 185 CFM 100 pints per day @ 280 CFM
Power
115 VAC, Single Phase, 60 Hz
5.1A operating current 6.9A operating current
Dehumidifier Inlet Air Conditions
Dehumidification: 50°F–104°F, 40°F dew point minimum
Ventilation: 40°F–140°F, 0% RH–99% RH (non-condensing)
Filter MERV 8, washable
Airflow
External Static
Pressure ("WC)
Airflow (CFM)
External Static
Pressure ("WC)
Airflow (CFM)
0.0 185 0.0 280
0.2 135 0.2 245
0.4 85 0.4 210
0.6 175
OTE: N Rated capacity and current draw measured
at 80°F/60% RH inlet conditions at 0.0 external static
pressure.
PREPARING THE UNIT FOR
INSTALLATION
IMPORTANT: Cut the strap securing the compressor
shipping support bracket and remove the strap and
shipping bracket.
See Figure 8
.
1. Clip off and remove the plastic straps securing the
compressor to the shipping bracket.
2. Remove the two screws securing the shipping
bracket to the housing. Remove and discard the
shipping bracket, and reinstall the two screws in the
dehumidifier.
2
1
90-1908
Figure 8: Preparing the Unit for Installation
1 - Clip Off Plastic Strap 2 - Remove Shipping
Bracket