Install Instructions
TABLE OF CONTENTS
Safety Instructions......................................................................................................1
Specifications..........................................................................................................2
Set Up Dehumidifier for Installation ......................................................................................3
Packaging Content......................................................................................................3
Duct Collars ...........................................................................................................4
Control Location........................................................................................................4
Location Considerations.................................................................................................5
Installation.............................................................................................................5
Leveling ..............................................................................................................5
Ductwork Installation ...................................................................................................5
Drain Tubing and Condensate Pump Installation ..............................................................................6
Float Switch Wiring.....................................................................................................7
Alert Light Mounting ....................................................................................................7
Model 76 – Crawl Space Control and Wiring ..............................................................................8
System Set-Up, Check & Start-Up ........................................................................................8
System Set-Up.........................................................................................................8
System Check .........................................................................................................9
Start-Up ..............................................................................................................9
High Dew Point / High Humidity Alert....................................................................................10
Troubleshooting .......................................................................................................10
Table 2 – Error Codes ..................................................................................................10
Table 3 – Troubleshooting Guide .........................................................................................11
Service Parts..........................................................................................................12
SPECIFICATIONS
Model E080CS Model E100CS
Shipping Weight
81 lbs. 82 lbs.
Unit Weight
63 lbs. 64 lbs.
Capacity
80°F, 60% RH Conditions
80 pints per day @ 185 CFM 100 pints per day @ 280 CFM
Power
115 VAC, Single Phase, 60Hz
5.1 Amps operating current 6.9 Amps operating current
Dehumidifier Inlet
Air Conditions
Dehumidification: 50°F – 104°F, 40°F dew point minimum
Ventilation: 40°F – 140°F, 0%RH – 99%RH (non-condensing)
Filter
MERV 8, washable
Airflow
185 CFM 280 CFM
NOTE: Rated capacity and current draw measured at 80°F/60%RH inlet conditions at 0.0 external static pressure.