Specification Sheet

APPLICATIONS
Main Return to Main Return - RECOMMENDED
• This application can be used when a supply duct is not available.
Air is pulled from the return duct, dehumidified, and returned to the return duct.
Assures that the dehumidified air is mixed with rest of the air in the duct before it re-enters the house.
• This application is for whole-home dehumidification.
AIR
RETURNSUPPLY
HANDLER
Dedicated Return to Main Supply or Dedicated Return to A/C Return
• This application can be used when a return or supply duct is not available.
Air is pulled through a dedicated return grille, dehumidified, and returned to the supply plenum or return.
• This application is for whole-home dehumidification.
AIR
RETURNSUPPLY
HANDLER
AIR
RETURNSUPPLY
HANDLER
Inlet and Outlet ducted to dedicated grilles
• For homes without duct work.
• Dries a specific area that has a moisture issue (basements, crawl spaces, sealed attics, etc.).
Dehumidifier can be located in a closet, mechanical room or unfinished area and ducted into a finished room.
Main Return to Main Supply
Air is pulled from the return duct, dehumidified, and returned to the supply plenum.
• This application is for whole-home dehumidification.
AIR
RETURNSUPPLY
HANDLER
Model 8620/8620W
with IAQ Control
Universal 2H/2C or 4H/2C HP
Event-Based™ Air Cleaning
Humidity or Ventilation
Wi-Fi touch screen (8620W)
Model 8910/8910W
with IAQ Control
Universal 3H/3C or 4H/2C HP
Event-Based™ Air Cleaning
Humidity and Ventilation
2 Part–3-Wire design
Wi-Fi touch screen (8910W)
Model 8920W
with IAQ Control
Universal 3H/3C or 4H/2C HP
Event-Based™ Air Cleaning
Humidity and Ventilation
2 Part–3-Wire design
Full color Wi-Fi touch screen
Model 76 Wall Mount
Dehumidifier Control
• On/O buttons
• Wall mounted living space control
Displays RH and controls to an RH value
• Remote control for crawl space
applications and sealed attics
Electrical External Remote
Input voltage
and current
Voltage: 24VAC +/20%
Current: 25mA (nominal),
50mA (max.) at 24VAC
Voltage: 35VDC (supplied by
dehumidifier control board)
Output Dry contact, normally open Communication (RS485)
Control External Remote
Control range
40%
80% RH
1 (less dry)–7 (more dry)
65°F–40°F dew point
Accuracy +/-5% RH
See dehumidifier
specifications
Dierential 3% RH
Low limit
40°F
dew point
50°F dry bulb, 40°F
dew point min.
High limit
99°F
dry bulb
105°F
dry bulb
MODEL 76 SPECIFICATIONS
Optional Wall-Mount Controls
AprilairePartners.com
Form No. 887 • 287607 6.19
©2019 Aprilaire Division of Research Products Corporation
APRILAIRE RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT NOTICE.
P.O. Box 1467
Madison, WI 53701-1467
800.334.6011 F: 608.257.4357
Installation Options For the Aprilaire 1830 Dehumidifiers
Shown in horizontal applications, can be installed in vertical applications as well.