Install Instructions
LOCATION CONSIDERATIONS
• Allow sufficient clearance for filter removal and to
prevent airflow obstruction
• Electrical service access will require the removal
of the side panel shown� Allow sufficient space for
service on this side of the unit�
• If locating the unit in an attic or crawl space, a
Model 76 Control mounted in the living space is
recommended�
• For attic installations, it is recommended that the
dehumidifier be suspended�
• Always install the dehumidifier in a condensate pan
when locating in or over a finished space�
DRAIN INSTALLATION
The drain outlet on the dehumidifier can be hard piped using a 3/4" PVC Slip x 3/4" MNPT fitting and 3/4" nominal drain tubing or the provided
3/4"MNPT x 3/4" hose barb fitting� 3/4" clear PVC tubing can be used to drain the dehumidifier� Always maintain a constant downward slope from the
dehumidifier to the drain and do not allow soft tubing to curl up which may result in air lock�
NOTE: PTFE thread seal tape is recommended for the threaded connection and hand tighten only� If hard pipe is used, PVC primer and cement is
recommended for the slip fit connection� Remove drain insert before priming and gluing in the PVC fitting� Replace drain insert after PVC glue has
fully dried�
CAUTION
Do not damage drain cover. The drain cover is a critical feature of the dehumidifier drain management system.
WARNING
Running the dehumidifier without the drain insert can lead to condensate leaks. See FIGURE 10.
TOP VIEW
FILTER
MINIMUM
CLEARANCE FOR FILTER
(EITHER SIDE)
15"
6" MINIMUM CLEARANCE
FOR PROPER AIR FLOW
ELECTRICAL SERVICE
ACCESS THIS SIDE
6 FT. POWER CORD
90-1840
FIGURE 9 – FILTER ACCESS CLEARANCE