HARD WIRING – E080H & E100H
WARNING
ELECTRICAL SHOCK HAZARD: 115-volts may cause serious injury or death from electrical shock. Disconnect and tag electrical service before
starting installation or field-service. Leave electrical service disconnected until installation or field-service is complete.
ELECTRICAL SHOCK HAZARD: An interrupted or broken ground may cause property damage, serious injury or death should an electrical fault
occur. The cabinet must be grounded in accordance with NEC ANSI/NFPA 70-2011 or local codes. In Canada, refer to Canadian Electrical Code
CSA C22.1.
FIRE HAZARD: Use of improper wire may cause serious injury, property damage or death due to fire. Do not use aluminum wire for electrical
service to the dehumidifier. Use only copper wire.
CAUTION
Use of an undersized circuit breaker may cause property damage and/or the need for mold remediation service. See SPECIFICATIONS for wire
and circuit breaker sizing.
The Model E080H and the Model E100H must be hard wired� An electrical disconnect switch can be installed as needed to comply with appropriate
codes or ordinances� The ON/OFF switch on the dehumidifier interrupts the 115 VAC service to the internal components of the dehumidifier, but does
not disconnect the power supply at the 115 VAC terminals on the dehumidifier
United States Installations: Make all electrical connections in accordance with the current edition of the NEC ANSI/NFPA 70 and any local codes or
ordinances that may apply
Canada Installations: Make all electrical connections in accordance with the current edition of the Canadian Electrical Code CSA C22�1 and any local
codes or ordinances that may apply
ELECTRICAL SPECIFICATIONS FOR HARD WIRING
MODEL E080H MODEL E100H
Voltage 110-120 VAC, 60 Hz, 1 phase 110-120 VAC, 60 Hz, 1 phase
Minimum Circuit Ampacity (MCA) 9A 12A
Maximum Fuse or Circuit Breaker Amps (MOP) 16A 20A
Minimum Wire Size AWG 14 14