Install Instructions

CONTROL LOCATION
The on-board control can be located on the top of the
dehumidifier or can be relocated to the front of the
dehumidifier if the control cannot be seen/accessed in
the top orientation� It may also be rotated 180 degrees
in either orientation as shown in FIGURE 6
TO MOVE THE CONTROL
1. Remove the front control panel cover
2. Remove the filter access door and filter
3. Detach the on-board control by removing the four
(4) screws around the control� NOTE: Use one hand
to support the bottom of the on-board control
when removing�
4. Keep the control in the unit and relocate to the front
access hole
5. Secure the control with the same four screws used
to attach the control to the top of the unit�
6. Secure the control panel cover to the top of the unit�
NOTE: E100V UI can be rotated but not relocated�
CONTROL
PANEL COVER
CONTROL
CONTROL
CONTROL
PANEL COVER
FILTER ACCESS DOOR
90-1884
90-2525
FIGURE 5 – CONTROL LOCATION
FIGURE 6 – CONTROL ROTATED 180 DEGREES