Install Instructions

DEH W/AC
90-1854
To allow dehumidification during
active air conditioning, select
ENABLED and press MODE�
90-1854
To disable dehumidification when
the air conditioning is on, select
DISABLED and press MODE�
RH OFFSET
90-1854
An offset can be applied to the
on-board humidity reading to
avoid discrepancies with other
humidity measuring devices in the
home� Use the or button
to select an offset from -5% to 5%�
Press MODE to exit the installer
set-up screens�
ZONE
90-1854
If installing the dehumidifier in
a single zone application, select
DISABLED and press MODE to go
to the EXTERNAL control screen
selections�
90-1854
If installing the dehumidifier
in a two-zone application, use
the
or button to select
ENABLED and press MODE to go
to the EXTERNAL control screen
selections�
EXTERNAL CONTROL
90-1854
If using the dehumidifier
on-board control select
DISABLED and press MODE to go
to the dehumidification with air
conditioning (DEH W/AC) screen
selections�
90-1854
If using a Model 76, Model 8910,
or Model 8620 as an external
control or other third-party
external control, such as a
thermostat with dehumidifier
outputs, use the or
button to select ENABLED
and press MODE to go to
the dehumidification with air
conditioning (DEH W/AC) screen
selections�
16