Use and Care Manual
MAINTENANCE
CLEAN OR REPLACE THE AIR FILTER
After initial installation the air filter should be checked and cleaned every 6 months. The CLEAN
FILTER service reminder will display on the on-board control screen every 6 months. To clear the
service message, press the UP and DOWN arrows simultaneously for 3 seconds.
Filter Cleaning Procedure
1. Turn the ON/OFF switch OFF.
2. Remove the filter access door from either side of the dehumidifier.
3. Slide the filter out of the dehumidifier.
4. Flush the filter with warm water and a mild detergent solution.
5. Shake off the excess water from the filter.
6. Replace the filter, making sure the filter is secured in both the top and bottom filter rails.
7. Replace the filter access door.
8. Turn the ON/OFF switch ON.
9. Press the UP and DOWN buttons simultaneously for 3 seconds to clear the service message.
90-1854
CAUTION
Do not use spray solvents or cleaners on or near the inlet side of the dehumidifier.
If desired, apply cleaner to a cloth and use to clean the cabinet.
CHECK THE DRAIN
DIAGNOSTIC CODES
The drain should be checked annually to ensure there are no blockages or air lock in the drain system. If the unit is not draining properly, have it
checked by a qualified service professional.
The on-board control will display a diagnostic code if an error should occur and service is required.
Contact your installing contractor if E1– E7 or E9 is displayed on the on-board control screen. E8 will be
displayed if the incoming air temperature is below 50°F, above 104°F, or when the dew point is below
40°F. When the incoming air is within the acceptable range, the dehumidifier will resume operation.
If the error persists, contact your installing contractor.