Specification
Dehumidier
PRINCIPLE OF OPERATION
The AprilAire E070 Crawl Space Dehumidier is designed to
dehumidify the air coming into the unit by passing the incoming
air over an evaporator coil to drop the air temperature below
the dew point of the air. Moisture is removed from the air and
drained out of the unit to a common oor or waste drain. The air
is then reheated in the condenser coil and exits the unit.
Dehumidication occurs until the set point is reached, then shuts
off until periodic sampling determines a need for operation.
APPLICATION
The E070 Dehumidier is the perfect solution for controlling
humidity in crawl spaces; protecting against structural damage,
pests and mold.
CIRCULATION
The E070 can also be programmed to circulate the air within
a crawl space. Circulating the air evens out relative humidity
levels and temperature in the space, eliminating variations
in the environment.
12.51
12.44
.38 TO 2
3/4" PIPE, INSIDE
24.84
4.00
8
8
4.00
32.84
90-02828
• Built-in automatic digital control with display.
Can be set up for dehumidication and
ventilation or zoning.
• Front mount control
• ½” EPS cabinet insulation
• Air discharge orientation at end of cabinet
• Washable MERV 8 lter (part number 5695) and
8” diameter inlet/outlet duct collars
• R32 refrigerant
• Corrosion-resistant aluminum coils
• 8’ power cord (plug type); hardwire option
not available
• 10°F-30°F discharge air temperature rise
• ¾” MNPT Threaded drain connection with
adapters for threaded connection for plastic
hose included
• 10’ drain tubing
• 5-year warranty
FEATURES
SPECIFICATIONS
Capacity
@ 80°F/60% RH
@73°F/60% RH
70 ppd
53 ppd
Energy Factor kW-h
@ 80°F/60% RH
@ 73°F/60% RH
2.1 L/kW-h
1.8 L/KW-h
Airflow @ varying E.S.P.
(external static pressure - dry coil)
0.0” w.c.
0.2” w.c.
0.4” w.c.
200 CFM
170 CFM
140 CFM
Voltage, phase,
frequency
120VAC, 1 phase, 60 Hz
Current draw
(3)
5.4 Amps
Noise
53 dBA ducted
Dimensions (cabinet only)
(4)
Width: 12½”, Height: 12½”, Length: 25”
Unit Weight
Shipping Weight
56 lbs.
72 lbs.
Inlet air operating
conditions during
Dehumidication:
50°F–104°F, 40°F
dew point min.
Ventilation:
40°F –140°F,
0% –99% RH
(non-condensing)
(3)
Rated capacity, energy factor and current draw measured at 80°F/60% RH inlet air at 0.0 ESP.
(4)
Height does not include adjustable feet. The width excludes the lter doors and length excludes
the duct collars.
SPECIFICATION SHEET
Model E070
Crawl Space Dehumidier