Spec Sheet

FEATURES
Control
(3)
Built-in digital control with display
Control mounting option Front mount only
Cabinet insulation ½" EPS
Air discharge orientation End of cabinet only
Inlet/Outlet duct collars 8" dia.
Backdraft damper at outlet N/A
Filter Washable MERV 8
(Part Number 5695)
Refrigerant R410A
Coil type
Corrosion-resistant aluminum
8' Power cord
Plug type
Hardwire option
No
Discharge air temperature rise 10°F–30°F
Drain connection
(4)
¾" MNPT Threaded
Included drain tubing 10' length
Warranty 5 Years
(3)
Built-in automatic control capable to be set up for dehumidification and ventilation or zoning.
(4)
Adapters for threaded connection for plastic hose included.
PRINCIPLE OF OPERATION
The Aprilaire E070 Crawl Space Dehumidifier is designed to
dehumidify the air coming into the unit by passing the incoming
air over an evaporator coil to drop the air temperature below the
dew point of the air. Moisture is removed from the air and drained
out of the unit to a common floor or waste drain. The air is then
reheated in the condenser coil and exits the unit.
Dehumidification occurs until the set point is reached, then shuts o
until periodic sampling determines a need for operation.
APPLICATION
The E070 Dehumidifier is the perfect solution for controlling
humidity in crawl spaces; protecting against structural damage,
pests and mold.
CIRCULATION
The E070 can also be programmed to circulate the air within a crawl
space. Circulating the air evens out relative humidity levels and
temperature in the space, eliminating variations in the environment.
Crawl Space Dehumidifier
Model E070 | Specification Sheet
33"
25"
12½"
ؾ" NPT
12½"
4"
7
43
50
"
19
50
" to 2"
7
43
50
"
4"
200 CFM
170 CFM
140 CFM
0.0” w.c.
0.2” w.c.
0.4” w.c.
SPECIFICATIONS
Capacity
@ 80°F/60% RH
@ 73°F/60% RH
70 ppd
53 ppd
Energy Factor
@ 80°F/60% RH 2.1 L/kW-h
@ 73°F/60% RH 1.8 L/KW-h
Airflow @ varying E.S.P.
(external static pressure - dry coil)
Voltage, phase, frequency 120VAC, 1 phase, 60 Hz
Current draw
(1)
5.8 Amps
Noise 53 dBA ducted
Dimensions:
(cabinet only)
(2)
Width 12½"
Height 12½"
Length 25"
Unit Weight
Shipping Weight
56 lbs.
72 lbs.
Inlet air operating conditions during
-Dehumidification: 50°F–104°F, 40°F
dew point min.
-Ventilation: 40°F –140°F, 0% –99% RH
(non-condensing)
(1)
Rated capacity, energy factor and current draw measured at 80°F/60% RH inlet air at 0.0 ESP.
(2)
Height does not include adjustable feet. The width excludes the filter doors and length
excludes the duct collars.