Installation Guide
ARN25F Fan - Radon
Installation & Operating Instructions
Please Read and Save These Instructions.
DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED. MAKE SURE ELECTRICAL
SERVICE TO FAN IS LOCKED IN “OFF” POSITION. DISCONNECT POWER BEFORE SERVICING FAN.
1. WARNING! For general ventilating use only. Do not use to exhaust hazardous, corrosive or explosive
materials, gases or vapors.
2. WARNING! Check voltage at the fan to insure it corresponds with nameplate.
3. WARNING! Normal operation of this device may affect the combustion airflow needed for safe operation of
fuel burning equipment. Check for possible backdraft conditions on all combustion devices after installation.
4. NOTICE! There are no user serviceable parts located inside the fan unit.
Do NOT attempt to open. Return unit to the factory. (See Warranty, p. 8, for details.)
5. WARNING! Do not leave fan unit installed on system piping without electrical power for more than 48 hours.
Fan failure could result from this non-operational storage.
6. WARNING! TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer. If you have questions, contact the
manufacturer. (See p. 8.)
b) Before servicing or cleaning unit, switch power off at service panel and lock the service
disconnecting means to prevent power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag,
to the service panel.
c) Installation work and electrical wiring must be done by qualified person(s) in accordance with all
applicable codes and standards, including fire rated construction.
d) Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney)
of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturers’
guidelines and safety standards such as those published by any National Fire Protection Association,
and the American Society for Heating, Refrigerating and Air Conditioning Engineers (ASHRAE), and the
local code authorities.
e) When cutting or drilling into a wall or ceiling, do not damage electrical wiring and other
hidden utilities.
f) Ducted fans must always be vented to outdoors.
g) If this unit is to be installed over a tub or shower, it must be marked as appropriate for the
application and be connected to a GFCI (Ground Fault Circuit Interrupter) protected branch circuit.
AprilAire Fan
Installation & Operating Instructions
ARN25F
AprilAire Fan
Installation & Operating Instructions
ARN25F
1.0 SYSTEM DESIGN CONSIDERATIONS
1.1 INTRODUCTION
The AprilAire Fan is intended for use by trained, professional, certified/licensed radon mitigators. The purpose
of these instructions is to provide additional guidance for the most effective use of the AprilAire Fan. These
instructions should be considered supplemental to current industry standards and federal, state, county and
local building codes and regulations. In the event of a conflict, those standards, codes, practices and
regulations take precedence over these instructions.
1.2 FAN SEALING
The AprilAire Fan is factory sealed; no additional caulk or other materials are required to inhibit air leakage.
1.3 ENVIRONMENTALS
The AprilAire Fan is designed to perform year-round in all but the harshest climates without additional concern
for temperature or weather. For installations in an area of severe cold weather, please contact AprilAire for
assistance. When not in operation, the fan should be stored in an area where the temperature is never less
than 32 degrees F or more than 100 degrees F.
1.4 ACOUSTICS
The AprilAire Fan, when installed properly, operates with little or no noticeable noise to the building occupants.
The velocity of the outgoing air should be considered in the overall system design. In some cases a “rushing”
sound of the outlet air may be audible. In these instances, the use of a Exhaust Muffler is recommended.
(To ensure quiet operation of inline and remote fans, each fan shall be installed using sound attenuation
techniques appropriate for the installation. For bathroom and general ventilation applications, at least 8 feet
of insulated flexible duct shall be installed between the exhaust or supply grille(s) and the fan(s). AprilAire
Fans are not suitable for kitchen range hood remote ventilation applications.)
1.5 GROUND WATER
In the event that a temporary high water table results in water at or above slab level, water may be drawn
into the riser pipes, thus blocking air flow to the AprilAire Fan. The lack of cooling air may result in the fan
cycling on and off as the internal temperature rises above the thermal cutoff. Should this condition arise, it is
recommended that the fan be turned off until the water recedes, allowing for return to normal operation.
1.6 SLAB COVERAGE
The AprilAire Fan can provide coverage up to 2000+ sq. ft. per slab penetration. This will primarily depend on
the sub-slab material in any particular installation. In general, the tighter the material, the smaller the area
covered per penetration. Appropriate selection of an AprilAire fan best suited for the sub-slab material can
improve slab coverage. The ARN15F is best suited for general purpose use. The ARN25F can be used where
additional airflow is required, and the ARNHPF is best suited for tight soil conditions. Additional suction points
can be added as required. It is recommended that a small pit (5 to 10 gallons in size) be created below the
slab at each suction hole.
3
2
61002082 B2209772 1015 E. Washington Ave., Madison, WI | aprilaire.com 61002082 B2209772 1015 E. Washington Ave., Madison, WI | aprilaire.com
8
61002082 B2209772 1015 E. Washington Ave., Madison, WI | aprilaire.com 61002082 B2209772 1015 E. Washington Ave., Madison, WI | aprilaire.com
IMPORTANT INSTRUCTIONS TO INSTALLER
Inspect the AprilAire® Fan for shipping damage within 15 days of receipt. Notify AprilAire of any damages
immediately. AprilAire is not responsible for damages incurred during shipping. However, for your benefit,
AprilAire does insure shipments.
There are no user serviceable parts inside the fan. Do not attempt to open the housing. Return unit to factory.
(See Warranty below).
Install the AprilAire Fan in accordance with all current industry standards and federal, state, county and local
building codes and regulations.
Provide a copy of this instruction or comparable radon system and testing information to the building
occupants after completing system installation.
Warranty
AprilAire® warrants that the Fan will be free from defects in materials and workmanship for a period of 12 months from the date of
installation or 18 months from the date of manufacture, whichever is sooner (the “Warranty Term”).
AprilAire® will replace any fan which fails due to defects in materials or workmanship during the Warranty Term. This Warranty is contingent
on installation of the Fan in accordance with the instructions provided. This Warranty does not apply to damage caused by repairs or
alterations made or attempted, or if the unit has been abused or misused. Warranty does not cover damage in shipment unless the
damage is due to the negligence of AprilAire®.
The Fan must be returned (at owner’s cost) to the AprilAire® factory. Any Fan returned to the factory will be discarded unless the owner
provides specific instructions along with the Fan when it is returned regardless of whether or not the Fan is actually replaced under this
warranty. If factory return is required, the customer assumes all shipping costs, including insurance, to and from factory. Proof of purchase
must be supplied upon request for service under this Warranty.
5-YEAR EXTENDED WARRANTY WITH PROFESSIONAL INSTALLATION.
AprilAire® will extend the Warranty Term of the Fan to 60 months (5 years) from date of installation or 66 months from date of manufacture,
whichever is sooner, provided that the Fan is installed by a professional radon mitigation contractor. Proof of purchase and/or proof of
professional installation may be required for service under this warranty. This extended warranty is not offered outside the continental
United States and Canada.
AprilAire® is not responsible for installation, removal or delivery costs associated with this Warranty.
LIMITATION OF WARRANTY
EXCEPT AS STATED ABOVE AND AS REQUIRED BY APPLICABLE LAW, THE FAN IS PROVIDED WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS
OR IMPLIED, INCLUDING, WITHOUT LIMITATION, IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. TO
THE EXTENT IMPLIED WARRANTIES CANNOT BE DISCLAIMED, THEY ARE LIMITED IN DURATION AND REMEDY TO THE SAME EXTENT AS THE
EXPRESS WARRANTY STATED ABOVE.
TO THE EXTENT PERMITTED BY LAW, AprilAire SHALL IN NO EVENT BE LIABLE FOR ANY DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR
CONSEQUENTIAL DAMAGES ARISING OUT OF, OR RELATING TO, THE FAN OR THE PERFORMANCE THEREOF. AprilAire’s AGGREGATE LIABILITY
HEREUNDER SHALL IN NO EVENT EXCEED THE AMOUNT OF THE PURCHASE PRICE OF THE FAN. THE SOLE AND EXCLUSIVE REMEDY UNDER THIS
WARRANTY SHALL BE THE REPLACEMENT OF THE FAN.
Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential
damages, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights
which vary from state to state.
For service under this Warranty, contact AprilAire for a Return
Material Authorization (RMA) number and shipping information.
No returns can be accepted without an RMA.
AprilAire
1015 East Washington Ave, Madison, WI USA
TEL 800.334.6011
Record the following information for your records:
Serial Number: Purchase Date: