Specifications
8 9
7 THERMOSTAT INSTALLER OPTIONS
The installer options can be accessed by pressing and
holding the ENTER key for seven seconds. The LCD
displays Option 01 for setting the number. (See Installer
Options Chart.)
Press or hold the NEXT key to advance to the next
option. The LCD will advance through to Option 15 and
then return to Option 01.
Press the ENTER key to save all options in nonvolatile
flash ram.
If only one wireless thermostat and control module are
used in an application, the thermostat can be left with
the factory default setting of and Zone = 01 and
Home = 01.
If multiple wireless thermostats and control
modules are used that are less than 500 feet away
from one another, each thermostat must be set to
a different Home number. For convenience, set
the Installer Options with the thermostat off the
subbase and in easy access of its control module.
Option Description
01
Zone number
Range 01 to 08
Default 01
02
Home number
Range 01 to 32
Default 01
03
Program Control Module with Zone
and Home address - Default 01
04
Equipment type
Range 00- G/E 01- Heat Pump
Default 00- G/E
05
Indoor Fan Operation
Range 00- Gas 01- Electric
Default 00- Gas
06
Minimum Off Time
Range 01 to 09 minutes
Default 00 minutes
07
Minimum Run Time
Range 01 to 09 minutes
Default 00 minutes
08
Maximum allowable heating setpoint
Range 60 to 85F
Default 85F
Option Description
09
Minimum allowable cooling setpoint
Range 55 to 80F
Default 65F
10
Heat/Cool Setpoint Differential
Range 02 to 06F
Default 02F
11
Stage 1 Temperature Differential
Range 01 to 04F
Default 01F
12
Stage 2 Temperature Differential
Range 01 to 10F
Default 03F
13
Stage 3 Temperature Differential
Range 01 to 12F
Default 05F
14
Staging Time
Range 0=OFF 1=ON
Default 0
15
Staging Time When 14 = 1 (ON)
Range 15 - 30 (1 Minute Increments)
Default 15
INSTALLER OPTIONS CHART
RESETTING FACTORY DEFAULTS
To reset the factory defaults, remove the batteries
and re-install them while holding down the SYSTEM
key. All prior changes will default to the factory
settings. This will require resetting the time of day
and programming schedules if necessary. Refer to the
Installer Options Chart default settings to make any