1 INSTALLATION
The control module should be installed close to the
equipment being controlled. Do not install it within
a metal enclosure that might interfere with wireless
communications. Only standard 18 gauge thermostat
wire is required to wire the module to the equipment.
Two #6 sheet metal mounting screws are included
or the module can be installed with double-backed
adhesive tape.
2 WIRING
The control module is powered by the 24VAC from
HVAC system The diagrams below show wiring when
configured for Gas / Electric and Heat Pump systems.
Refer to the wiring diagrams on the following page.
CONTROL MODULE
2.65”
.187” DIA.
2PLCS
4.57”
1.10”
5.09”
B/1W
O
E/2W
1Y
2Y
G
R
C
COM
GAS /ELECTRICHVAC SYSTEM
R
Y1
Y2
W2
W1
G
W1/B
O
W2/E
Y1
Y2
G
R
C
WIRING – GAS / ELECTRIC (UP TO 2 HEAT / 2 COOL)
COM
HEAT PUMP SYSTEM
R
Y1
Y2
W2/E
O
B
G
W1/B
O
W2/E
Y1
Y2
G
R
C
WIRING – HEAT PUMP (UP TO 3 HEAT / 2 COOL)